THE CARDIAC OUTPUT AND OXYGEN CONSUMPTION OF NINE SURGICAL PATIENTS BEFORE AND AFTER OPERATION 1
Open Access
- 1 September 1938
- journal article
- research article
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 17 (5) , 571-579
- https://doi.org/10.1172/jci100982
Abstract
The cardiac output and O consumption of 9 surgical patients were measured by the ethyl iodide method before and after operation. Preliminary tests showed that ether vapor does not affect the accuracy of the chemical method for the analysis of ethyl iodide vapor, and that the solubility of ethyl iodide in the blood of patients anesthetised with ether is essentially unaffected. The average cardiac output in the period of recovery from ether anesthesia was decreased by 41% of the basal preoperative level. The changes in O consumption were occasionally large but not consistent.This publication has 6 references indexed in Scilit:
- THE DETERMINATION OF THE CARDIAC OUTPUT IN MAN AT BRIEF INTERVALS BY A MODIFICATION OF THE ETHYL IODIDE METHOD 1Journal of Clinical Investigation, 1938
- CHANGES IN BLOOD AND INTERSTITIAL FLUID RESULTING FROM SURGICAL OPERATION AND ETHER ANESTHESIA 1Journal of Clinical Investigation, 1938
- A CLINICAL STUDY OF THE ACTION OF 10 COMMONLY USED DRUGS ON CARDIAC OUTPUT, WORK AND SIZE; ON RESPIRATION, ON METABOLIC RATE AND ON THE ELECTROCARDIOGRAMJournal of Clinical Investigation, 1937
- THE CALCULATION OF CARDIAC OUTPUT AND EFFECTIVE PERIPHERAL RESISTANCE FROM BLOOD PRESSURE MEASUREMENTS WITH AN APPENDIX ON THE SIZE OF THE AORTA IN MANAmerican Journal of Physiology-Legacy Content, 1935
- STUDIES OF THE HEART AND CIRCULATION IN DISEASE; ESTIMATIONS OF BASAL CARDIAC OUTPUT, METABOLISM, HEART SIZE, AND BLOOD PRESSURE IN 235 SUBJECTSJournal of Clinical Investigation, 1934
- AN IMPROVED METHOD FOR THE DETERMINATION OF CARDIAC OUTPUT IN MAN BY MEANS OF ETHYL IODIDEAmerican Journal of Physiology-Legacy Content, 1928