Non-invasive coronary angiography with 16-slice spiral computed tomography: image quality in patients with high heart rates
- 24 February 2006
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 16 (7) , 1434-1441
- https://doi.org/10.1007/s00330-006-0155-z
Abstract
The purpose of this study was to assess segment image quality at high heart rates using 16-slice computed tomography and differential reconstruction for major coronary vessels. According to the following protocol, 16-slice CT coronary angiography in 46 patients with a mean heart rate of 86.3+/-11.8 was reconstructed. At three transverse planes, preview series were obtained and motion artifacts evaluated in 5% increments from 0-95% within the cardiac cycle. Relying on image quality in the previews, reconstructions were performed at three z-positions for each patient. Segment image quality was assessed in terms of artifacts and visibility. The effects of heart rate and trigger delay on image quality were analyzed. Optimal image quality was achieved at 25 to 35% of the cardiac cycle for the left circumflex (CX) and right coronary artery (RCA) or 30 to 40% for the left main (LM) and left anterior descending artery (LAD). Sixteen-slice CT and differential reconstruction produced good image quality with a low percentage of motion-degraded proximal and middle segments (8.8%). Grades were 1.5 for the LM, 1.9 for the LAD, 2.0 for the CX and 2.3 for the RCA. At high heart rates, good image quality of the coronary arteries is achieved by 16-slice CT and a sophisticated reconstruction strategy at peak to late systole.Keywords
This publication has 33 references indexed in Scilit:
- Evaluation of computed tomography coronary angiography in patients with a high heart rate using 16-slice spiral computed tomography with 0.37-s gantry rotation timeEuropean Radiology, 2005
- Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary AngiographyAmerican Journal of Roentgenology, 2005
- Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation timeEuropean Radiology, 2004
- Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: Initial clinical resultsJournal of the American College of Cardiology, 2004
- Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar ReconstructionCirculation, 2003
- Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomographyClinical Imaging, 2002
- Coronary Magnetic Resonance Angiography for the Detection of Coronary StenosesNew England Journal of Medicine, 2001
- American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on Cardiac Catheterization Laboratory Standards: A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents endorsed by the American Heart Association and the Diagnostic and Interventional Catheterization Committee of the Council on Clinical Cardiology of the AHAPublished by Elsevier ,2001
- Coronary angiography with multi-slice computed tomographyThe Lancet, 2001
- Cardiac Motion of Coronary Arteries: Variability in the Rest Period and Implications for Coronary MR AngiographyRadiology, 1999