Error Analysis for the Determination of Cerebral Blood Flow with the Continuous Inhalation of 15O-Labeled Carbon Dioxide and Positron Emission Tomography
- 31 January 1982
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 6 (1) , 116-124
- https://doi.org/10.1097/00004728-198202000-00020
Abstract
The inhalation of C15O2 can be used for determining local cerebral blood flow (LCBF) using a quantitative model. The determination of LCBF in 3 dimensions using positron emission tomography (PET) involves errors due to counting statistics, data manipulation and the estimation of parameters in the mathematical model. Error propagation and its relation to the radiation dose to the subject''s lungs were examined. An expression was derived for the root mean square uncertainty in LCBF as a function of LCBF, the spatial resolution and the sensitivity of the PET instrument, the normal variability in the brain-blood partition coefficient for H2O, and absorbed radiation dose to the subject''s lungs. The error in LCBF increases as CBF increases. At a normal cortical LCBF of 80 ml/100 g-min and a PET instrument with a 1.65 cm FWHM [full width at half maximum] resolution and a 46,000 cps [cycle/second] per .mu.Ci/g sensitivity per slice, an error (coefficient of variation) of 5% results from an inhaled activity of 250 mCi, resulting in a lung dose of 5 rads, the maximum permissible dose allowed. For a more acceptable dose of 1.2 rads, the error is 7%. At a higher resolution (0.8 cm FWHM) and lower sensitivity (15,000 cps per .mu.Ci/g per slice), errors became on the order of 28% for a lung dose of 1.2 rads. Errors due to other factors such as blood sample counting, and instrument cross calibration can be virtually eliminated by proper technical strategies. This consideration of error and its relation to radiation dose is important for the application of this inhalation technique for the quantification of LCBF.This publication has 10 references indexed in Scilit:
- Quantitative Measurement of Regional Cerebral Blood Flow and Oxygen Metabolism in Man Using 15O and Positron Emission TomographyJournal of Computer Assisted Tomography, 1980
- A theoretical study of quantitative flow measurements with constant infusion of short-lived isotopesPhysics in Medicine & Biology, 1979
- RESOLUTION RATES OF PULMONARY-EMBOLISM ASSESSED BY SERIAL POSITRON IMAGING WITH INHALED O-15-LABELED CARBON-DIOXIDE1979
- The [18F]fluorodeoxyglucose method for the measurement of local cerebral glucose utilization in man.Circulation Research, 1979
- The synthesis of 13N-labelled nitrous oxideThe International Journal of Applied Radiation and Isotopes, 1978
- QUANTITATIVE POTENTIALS OF DYNAMIC EMISSION COMPUTED TOMOGRAPHY1978
- MODEL FOR REGIONAL CEREBRAL OXYGEN DISTRIBUTION DURING CONTINUOUS INHALATION OF O-15(2), CO-O-15, AND CO2-O-151978
- DESIGN AND PERFORMANCE-CHARACTERISTICS OF A WHOLE-BODY POSITRON TRANSAXIAL TOMOGRAPH1976
- Regional Blood Flow by Fractional Distribution of IndicatorsAmerican Journal of Physiology-Legacy Content, 1958
- Exchange of Water Between Blood and TissuesAmerican Journal of Physiology-Legacy Content, 1952