Contrast Media Tonicity: Part I. Effects Upon IV-DSA Time-Concentration Curve Peak and Width: Experimental Studies
- 1 March 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 21 (3) , 240-247
- https://doi.org/10.1097/00004424-198603000-00009
Abstract
Prior to the formation of an intravenous digital subtraction angiography (IV-DSA) image, contrast medium passes through the lesser circulation and is diluted by the blood volume of the heart and lungs. If the contrast medium alone influences central blood volume or cardiac output, the shape of the resultant timeconcentration curve may be degraded. To the extent that contrast medium tonicity reduces curve peak or increases width, image quality for mask mode IV-DSA will suffer. To quantify the effect of contrast medium tonicity upon curve shape, contrast medium (1) at increasing iodine concentration and increasing osmolality and (2) at constant iodine concentration and increasing osmolality was injected into the right atria of mongrel dogs. In both experiments, increasing osmolality was associated with an increase in central blood volume (CBV) and cardiac output. With an increase in CBV, curve peak fell. With an increase in both CBV and cardiac output, curve width was not influenced by increasing osmolality. The effect of osmolality upon CBV was highly variable; in these experiments CBV was influenced more by subject-to-subject variability. However, on the average, higher tonicity contrast media produced curves with lower peaks. These studies suggest that isotonic contrast medium does not increase CBV and that isotonic contrast medium is preferable to hypertonic contrast medium for IV-DSA image formation.This publication has 10 references indexed in Scilit:
- Bolus geometry and dynamics after intravenous contrast medium injection.Radiology, 1984
- Effect of volume and rate of contrast medium injection on intravenous digital subtraction angiographic contrast medium curvesJournal of the American College of Cardiology, 1984
- An Experimental Evaluation of Central vs. Peripheral Injection for Intravenous Digital Subtraction Angiography (IV-DSA)Investigative Radiology, 1984
- Extravascular lung water: effects of ionic and nonionic contrast media.Radiology, 1983
- Effects of contrast media on pulmonary hemodynamics: comparison of ionic and non-ionic agents.Radiology, 1983
- Digital vascular imaging: practical aspects.Radiology, 1983
- Intravenous digital subtraction angiography: peripheral versus central injection of contrast material.Radiology, 1983
- A Quantitative In Vivo Comparison of Six Contrast Agents by Digital Subtraction AngiographyInvestigative Radiology, 1982
- Effect of concentrated contrast media during angiography on plasma volume and plasma osmolalityAmerican Heart Journal, 1965
- Extra-Period Latin-Square Change-Over DesignsJournal of Dairy Science, 1957