High‐resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high‐speed incorporation of RF field inhomogeneities (DESPOT1‐HIFI)
Open Access
- 25 September 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (4) , 1106-1111
- https://doi.org/10.1002/jmri.21130
Abstract
Purpose To investigate an alternative approach to correct for flip angle inaccuracies in the driven equilibrium single pulse observation of T1 (DESPOT1) T1 mapping method. Materials and Methods While DESPOT1 is a robust method for rapid whole-brain voxelwise mapping of the longitudinal relaxation time, the approach is inherently sensitive to inaccuracies in the transmitted flip angle, defined by the B1 field, which become more severe with increased field. Here we propose an extension of the DESPOT1 technique, involving the additional acquisition of an inversion-prepared SPGR image alongside the conventional multiangle DESPOT1 data. From these combined data both B1 and T1 may be determined with high accuracy and precision. The method is evaluated at 3T with phantom and in vivo imaging experiments, with derived T1 estimates compared with values calculated from multiple inversion time inversion recovery data. Results The method provides robust correction of flip angle variations, with less than 5% error compared with reference values for T1 between 300 msec and 2500 msec. Conclusions The described approach, dubbed DESPOT1-HIFI, permits whole-brain T1 mapping at 3T, with 1 mm3 isotropic voxels, in a clinically feasible time (≈10 minutes) with T1 accuracy greater than 5% and with high precision. J. Magn. Reson. Imaging 2007;26:1106–1111.Keywords
This publication has 19 references indexed in Scilit:
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- T1, T2 relaxation and magnetization transfer in tissue at 3TMagnetic Resonance in Medicine, 2005
- Visualization of thalamic nuclei on high resolution, multi‐averaged T1 and T2 maps acquired at 1.5 THuman Brain Mapping, 2005
- Small tip angle three‐dimensional tailored radiofrequency slab‐select pulse for reduced B1 inhomogeneity at 3 TMagnetic Resonance in Medicine, 2005
- Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady stateMagnetic Resonance in Medicine, 2003
- Imaging of the active B1 field in vivoMagnetic Resonance in Medicine, 1996
- Surface coil MR imaging of the human brain with an analytic reception profile correctionJournal of Magnetic Resonance Imaging, 1995
- An MRI phantom material for quantitative relaxometryMagnetic Resonance in Medicine, 1987
- Optimizing the precision in T1 relaxation estimation using limited flip anglesMagnetic Resonance in Medicine, 1987
- Driven-equilibrium single-pulse observation of T1 relaxation. A reevaluation of a rapid “new” method for determining NMR spin-lattice relaxation timesJournal of Magnetic Resonance (1969), 1985