A rotating and warping projector/backprojector for fan-beam and cone-beam iterative algorithm
- 1 December 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 41 (6) , 2807-2811
- https://doi.org/10.1109/23.340651
Abstract
A rotating-and-warping projector/backprojector is proposed for iterative algorithms used to reconstruct fan-beam and cone-beam single photon emission computed tomography (SPECT) data. The development of a new projector/backprojector for implementing attenuation, geometric point response, and scatter models is motivated by the need to reduce the computation time yet to preserve the fidelity of the corrected reconstruction. At each projection angle, the projector/backprojector first rotates the image volume so that the pixelized cube remains parallel to the detector, and then warps the image volume so that the fan-beam and cone-beam rays are converted into parallel rays. In the authors' implementation, these two steps are combined so that the interpolation of voxel values are performed only once. The projection operation is achieved by a simple weighted summation, and the backprojection operation is achieved by copying weighted projection array values to the image volume. An advantage of this projector/backprojector is that the system point response function can be deconvolved via the Fast Fourier Transform using the shift-invariant property of the point response when the voxel-to-detector distance is constant. The fan-beam and cone-beam rotating-and-warping projector/backprojector is applied to SPECT data showing improved resolution.Keywords
This publication has 15 references indexed in Scilit:
- Quantitative SPECT brain imaging: effects of attenuation and detector responseIEEE Transactions on Nuclear Science, 1993
- 3-D maximum a posteriori estimation for single photon emission computed tomography on massively-parallel computersIEEE Transactions on Medical Imaging, 1993
- Frequency domain implementation of the three-dimensional geometric point response correction in SPECT imagingIEEE Transactions on Nuclear Science, 1992
- Nonuniform attenuation correction using simultaneous transmission and emission converging tomographyIEEE Transactions on Nuclear Science, 1992
- Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensionsPhysics in Medicine & Biology, 1992
- Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correctionIEEE Transactions on Nuclear Science, 1991
- A projector, backprojector pair which accounts for the two-dimensional depth and distance dependent blurring in SPECTIEEE Transactions on Nuclear Science, 1990
- The geometric transfer function for cone and fan beam collimatorsPhysics in Medicine & Biology, 1990
- The geometric transfer function component for scintillation camera collimators with straight parallel holesPhysics in Medicine & Biology, 1980