To investigate the impact of a device replacement in blood pressure measurement in epidemiological studies on comparison and interpretation of epidemiological data by replacing traditional aneroid manometry with automated oscillometric devices. Within the context of a continuing epidemiological study (EPIC-Potsdam Study), blood pressure measurements were performed simultaneously with an aneroid sphygmomanometer and an automated oscillometric device for each subject. We randomly selected 400 men and women from the main study population and one observer performed three consecutive blood pressure measurements for each subject according to a standardized procedure. In total, 10 oscillometric devices of the same type were used. Demographic and anthropometric data for each subject were obtained by trained interviewers. The mean difference between the aneroid and the oscillometric measurements of systolic blood pressure was 0.2 +/- 5.6 mmHg (aneroid value greater, NS), whereas the mean difference in diastolic blood pressure, 0.5 +/- 3.5 mmHg (aneroid value smaller), attained statistical significance (P = 0.0001). Estimates of prevalence for hypertension differed by 0.4% for women, and by 2.9% for men. Associations with the differences between methods were observed with age, blood pressure, lean body mass, upper arm circumference and specific devices without indicating a strong and consistent pattern. The use of automated oscillometric devices in epidemiological studies introduces a bias of very small magnitude compared with use of the aneroid method. The effect of the change to this automated measurement procedure on prevalence estimates is small but might affect comparability of data. Minor differences in measurement performance between devices of one type might affect population parameters.Keywords
This publication has 16 references indexed in Scilit:
- The EPIC Project: rationale and study design. European Prospective Investigation into Cancer and NutritionInternational Journal of Epidemiology, 1997
- Blood pressure measurement error: its effect on cross-sectional and trend analysesJournal of Clinical Epidemiology, 1994
- Terminal digit preference, random error, and bias in routine clinical measurement of blood pressureJournal of Clinical Epidemiology, 1993
- Accuracy and Reproducibility of 30 Devices for Self-Measurement of Arterial Blood PressureAmerican Journal of Hypertension, 1993
- Nutrition and cancer: Background and rationale of the European Prospective Investigation into Cancer and Nutrition (EPIC)Annals of Oncology, 1992
- INACCURACY OF ELECTRONIC SPHYGMOMANOMETERSClinical and Experimental Pharmacology and Physiology, 1992
- The Hypertension Prevention Trial: Assessment of the Quality of Blood Pressure MeasurementsAmerican Journal of Epidemiology, 1991
- The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systemsJournal Of Hypertension, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Body fat assessed from total body density and its estimation from skinfold thickness: measurements on 481 men and women aged from 16 to 72 YearsBritish Journal of Nutrition, 1974