Intracoronary blood flow velocity and transstenotic pressure gradient using sensor‐tip pressure and doppler guidewires: A new technology for the assessment of stenosis severity in the catheterization laboratory
- 1 April 1993
- journal article
- case report
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 28 (4) , 311-319
- https://doi.org/10.1002/ccd.1810280408
Abstract
In a patient undergoing percutaneous balloon angioplasty of a stenotic proximal right coronary artery the transstenotic pressure gradient was measured using a “0.018” guidewire with a distal optical microsensor. Blood flow velocity was measured proximal to the stenosis using a “0.018” Doppler guidewire. Transstenotic pressure gradient and blood flow velocity were measured in baseline conditions and after intracoronary injection of 12.5 mg of papaverine. Coronary blood flow was calculated from the measured blood flow velocity and the corresponding cross‐sectional area. The measured pressure gradients were compared with the values derived from the stenosis geometry assessed with quantitative coronary angiography (automated edge detection measurements in two orthogonal views, assuming an elliptical cross‐sectional area). The measured transstenotic pressure gradient was 15 mm Hg in baseline conditions and 42 mm Hg at the peak effect of the papaverine injection. A 50% flow velocity increase was observed at peak hyperemia (time‐averaged maximal flow velocity = 30 cm/s before and 45 cm/s after papaverine). The transstenotic pressure gradient calculated from the measured stenosis geometry was 20 mm Hg and 42 mm Hg in baseline and hyperemic conditions, respectively. The combined use of a pressure and a Doppler guidewire provides a complete assessment of the transstenotic pressure/coronary flow velocity relation at rest and after pharmacologically induced hyperemia and allows the characterization of stenosis hemodynamics and functional severity.Keywords
This publication has 27 references indexed in Scilit:
- Intravascular ultrasound. Research technique or clinical tool?Circulation, 1992
- Calibration using angiographic catheters as scaling devices — Importance of filming the catheters not filled with contrast mediumThe American Journal of Cardiology, 1992
- Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.Circulation, 1992
- Prevention of restenosis after percutaneous transluminal coronary angioplasty with thromboxane A2-receptor blockade. A randomized, double-blind, placebo-controlled trial. Coronary Artery Restenosis Prevention on Repeated Thromboxane-Antagonism Study (CARPORT).Circulation, 1991
- The effect of coronary angioplasty on coronary flow reserve.Circulation, 1988
- Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.Circulation, 1985
- Effect of perfusion pressure distal to a coronary stenosis on transmural myocardial blood flow.Circulation, 1982
- Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation.Circulation, 1977
- Pressure drop across artificially induced stenoses in the femoral arteries of dogs.Circulation Research, 1975
- Application of Heated-Film Velocity and Shear Probes to Hemodynamic StudiesCirculation Research, 1968