Discrepancies Between Catheter Tip and Tissue Temperature in Cooled-Tip Ablation
- 16 August 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 112 (7) , 954-960
- https://doi.org/10.1161/circulationaha.104.492439
Abstract
Background— It is not known whether catheter tip temperatures with a cooled-tip ablation can be reliably extrapolated to estimate actual tissue temperatures. The relationship between catheter tip temperatures, tissue temperatures, power, and microbubble formation is not known. Methods and Results— Nine dogs underwent 111 radiofrequency energy deliveries at the pulmonary vein ostia with a cooled-tip catheter. Catheter tip and tissue temperatures were markedly discrepant. Catheter tip temperature plateaus at 36°C to 39°C with increasing power, whereas tissue temperature increases to a mean of 75±3°C at 45 W (maximum temperature >100°C). Seventy-two energy deliveries were performed, titrating power to microbubble formation guided by intracardiac echocardiography. Type I and II microbubble formation occurred in 45 (63%) and 19 (26%) ablations, respectively. Type I microbubble emergence occurred at lower powers (21±8 versus 26±4 W; P=0.05), catheter tip temperatures (38±5°C versus 48±10°C; P=0.02), and tissue temperatures (65±19°C versus 81±9°C; PPConclusions— Catheter tip and tissue temperatures are markedly discrepant during cooled-tip ablation. Type I and II microbubble formation occurs at overlapping power and catheter tip and tissue temperature ranges. Neither the absence of microbubbles nor the presence of type I microbubble formation ensures against excessive tissue heating. The appearance of microbubbles may indicate possible tissue overheating and signal a need to decrease energy.Keywords
This publication has 17 references indexed in Scilit:
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- Abstract session 36: devices-ventricular function/resynchronization therapy VI: pacing therapies in heart failure: RV LV or bothHeart Rhythm, 2004
- Pulmonary Vein Stenosis After Radiofrequency Ablation of Atrial FibrillationCirculation, 2003
- Phased-Array Intracardiac Echocardiography Monitoring During Pulmonary Vein Isolation in Patients With Atrial FibrillationCirculation, 2003
- Effect of Heating on Pulmonary Veins:Journal of Cardiovascular Electrophysiology, 2003
- Why a Large Tip Electrode Makes a Deeper Radiofrequency Lesion:Journal of Cardiovascular Electrophysiology, 1998
- Biophysical characteristics of radiofrequency lesion formation in vivo: Dynamics of catheter tip–tissue contact evaluated by intracardiac echocardiographyAmerican Heart Journal, 1997
- Histologic Evolution of Radiofrequency Lesions in an Old Human Myocardial Infarct Causing Ventricular TachycardiaJournal of Cardiovascular Electrophysiology, 1995
- Myocardial Temperature Response During Radiofrequency Catheter AblationPacing and Clinical Electrophysiology, 1995
- Coagulation of Ventricular Myocardium Using Radiofrequency Alternating Current: Bio‐Physical Aspects and Experimental FindingsPacing and Clinical Electrophysiology, 1989