Megavoltage imaging with low Z targets: Implementation and characterization of an investigational system
- 1 October 1998
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 25 (10) , 1910-1918
- https://doi.org/10.1118/1.598380
Abstract
The poor quality of stereotactic radiotherapy portal images is a limiting factor in precise image registration. To alleviate this problem, a low atomic number target was implemented on our Siemens MXE linear accelerator. This investigational system was used to assess the performance of various target materials by filming an aluminum contrast object. Beryllium, carbon and conventional target materials were studied. The bremsstrahlung spectra of these materials were simulated using Monte Carlo techniques. These spectra were used to calculate the dependence of narrow beam contrast on phantom thickness for verification of the data measured from film. A Monte Carlo simulation of the beryllium spectrum in a wide beam geometry was used to evaluate the effect of phantom‐to‐film distance on contrast. Although the same degree of contrast improvement with distance was not realized in practice, the improvement in image quality rivaled that achieved using a scatter reduction grid. A comparison of conventional localization images of the head and neck of an anthropomorphic phantom with images produced with a beryllium or carbon target and a mammography film and screen system supports earlier suggestions that the technique is clinically useful.Keywords
This publication has 18 references indexed in Scilit:
- X‐ray sources of medical linear accelerators: Focal and extra‐focal radiationMedical Physics, 1993
- Computer‐assisted positioning of radiotherapy patients using implanted radiopaque fiducialsMedical Physics, 1993
- Automated determination of patient setup errors in radiation therapy using spherical radio‐opaque markersMedical Physics, 1993
- Low-energy imaging with high-energy bremsstrahlung beams: Analysis and scatter reductionMedical Physics, 1993
- Portal film enhancement: Technique and clinical utilityInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Angular distribution of bremsstrahlung from 15‐MeV electrons incident on thick targets of Be, Al, and PbMedical Physics, 1991
- Radiosurgery with unflattened 6‐MV photon beamsMedical Physics, 1991
- Dose distributions in radiosurgeryMedical Physics, 1990
- Low-energy imaging with high-energy bremsstrahlung beamsMedical Physics, 1989
- A quantitative assessment of portal film contrast as a function of beam energyMedical Physics, 1986