Effect of Skin Electrode Location on Radiofrequency Ablation Lesions: An In Vivo and a Three‐Dimensional Finite Element Study
- 1 December 1998
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 9 (12) , 1325-1335
- https://doi.org/10.1111/j.1540-8167.1998.tb00108.x
Abstract
Skin Electrode Location Affects RF Ablation Lesions. Introduction: Objectives: To assess the effect of skin electrode location on radiofrequency (RF) ablation lesion dimensions and energy requirements. Background: Little is known about the effects of skin electrode location on RF ablation lesion dimensions and efficiency. Methods and Results: Temperature‐controlled ablation at 60°C for 60 seconds was performed in six sheep. Paired lesions were created in the lateral, anterior, posterior, and septal walls of both the ventricles. For group 1 lesions, the skin electrode was positioned directly opposite the catheter tip (optimal). For group 2 lesions, we used either the standard posterior location or an anterior location if the posterior skin electrode location was used for group 1. Group 1 lesions were 5.8 × 0.8 mm deep and 9.3 × 1.9 mm wide, compared with 4.6 × 1.0 m deep and 7.7 × 1.9 mm wide group 2 lesions (P < 0.001). Group 1 lesion dimensions also bad less variability. A finite element model was used to simulate temperature‐controlled ablation and to study the effect of skin electrode locations on lesion dimensions, ablation efficiency, and blood beating. The optimal location was 1.6 times more efficient, and the volume of blood heating to ≥ 90° C was 0.005 mm3 for optimal versus 2.2 mm3 for the nonoptimal location. Conclusion: Optimal skin electrode placement: (1) creates deeper and larger lesions; (2) reduces lesion size variability; and (3) decreases blood beating.Keywords
This publication has 30 references indexed in Scilit:
- Radiofrequency catheter ablation for control of frequent ventricular tachycardia with healed myocardial infarctionThe American Journal of Cardiology, 1995
- Theory of heat transfer-irreversible power plants—II. The optimal allocation of heat exchange equipmentInternational Journal of Heat and Mass Transfer, 1995
- Numerical model for radio-frequency ablation of the endocardium and its experimental validationIEEE Transactions on Biomedical Engineering, 1994
- A computer simulation of radio-frequency ablation of the endocardiumIEEE Transactions on Biomedical Engineering, 1994
- Increasing catheter ablation lesion size by simultaneous application of radiofrequency current to two adjacent sitesAmerican Heart Journal, 1993
- The Biophysics of Radiofrequency Catheter Ablation in the Heart: The Importance of Temperature MonitoringPacing and Clinical Electrophysiology, 1993
- Should a VVIR Pacemaker Increase the Heart Rate with Standing?Pacing and Clinical Electrophysiology, 1992
- The Effect of Electrode Design on the Efficiency of Delivery of Radiofrequency Energy to Cardiac Tissue In VitroPacing and Clinical Electrophysiology, 1989
- Spatial and temporal frequency-dependent conductivities in volume-conduction calculations for skeletal muscleMathematical Biosciences, 1988