A simple algorithm for planar image registration in radiation therapy
- 2 June 1998
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 25 (6) , 824-829
- https://doi.org/10.1118/1.598292
Abstract
A simple algorithm is presented for planar image registration and the method is applied to the simulator and portal image registration for patient setup verification in radiation therapy. Basically, the algorithm follows the concept proposed by Balter et al. [Med. Phys.19, 329–334 (1992)], which converts the problem of open curve registration into matching a series of points along the curves. Balter's algorithm consists of three steps: (1) to determine a common starting point for each curve pair, (2) acquire two corresponding point sets along each curve, and (3) obtain a global transform matrix by matching two point sets. We integrate all three steps into one simple procedure which fits the sampled points along the intended curve pair by taking the relative path length shift as an independent fitting parameter. After being modified, the algorithm is able to take the different magnification factors of images into account, and it avoids curvature calculations. Numerical simulation as well as clinical and phantom images have been utilized to test the accuracy of the algorithm. The typical errors are less than 1 mm in translation and 1° in rotation. We also made a comparison study with the chamfer method. The results of the two methods agree to within 0.5 mm in translation and 0.5° in rotation.Keywords
This publication has 22 references indexed in Scilit:
- Alignment of multi-segmented anatomical features from radiation therapy images by using least square fittingMedical Physics, 1996
- Investigation of a phase-only correlation technique for anatomical alignment of portal images in radiation therapyPhysics in Medicine & Biology, 1996
- Core-based portal image registration for automatic radiotherapy treatment verificationInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Methods for fully automated verification of patient set-up in external beam radiotherapy with polygon shaped fieldsPhysics in Medicine & Biology, 1994
- An evaluation of two methods of anatomical alignment of radiotherapy portal imagesInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Optimization and evaluation of landmark-based image correlationPhysics in Medicine & Biology, 1992
- A method for the measurement of field placement errors in digital portal imagesPhysics in Medicine & Biology, 1990
- Hierarchical chamfer matching: a parametric edge matching algorithmPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1988
- An efficient method for finding the minimum of a function of several variables without calculating derivativesThe Computer Journal, 1964