A Model of the Geometrical Changes in Aortic Valve Leaflets in Response to Leaflet Extension and Variable Boundary Conditions
- 1 March 1992
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 206 (1) , 7-14
- https://doi.org/10.1243/pime_proc_1992_206_256_02
Abstract
The function, deformation and performance of heart valve leaflets are dependent on the material properties and the geometry of the leaflet. As the leaflet acts as a constrained membrane the geometry is dependent on the boundary condition applied to the leaflet and any permanent extension of the leaflet. Both of these factors are varied during the preparation of frame-mounted porcine bioprosthetic heart valves and surgical insertion of free-sewn valves. This can result in abnormal geometry and function. A mathematical model has been developed which describes these changes in geometry of a cylindrical leaflet as a function of the diameter of the aortic root (boundary conditions) and the length (or permanent extension) of the leaflet. Both the angle of inclination and the radius of curvature of the cylindrical leaflet were reduced with increased leaflet length or decreased aortic diameter. Agreement was found between the model predictions and experimental observations in porcine bioprosthetic heart valves, where abnormal leaflet geometries are produced by non-physiological boundary conditions and permanent set of the leaflets by fixation with glutaraldehyde. The general solutions developed in this model allow leaflet geometries to be predicted for a range of conditions in free-sewn and frame-mounted valves.Keywords
This publication has 26 references indexed in Scilit:
- Hydrodynamic Function of Second Generation Porcine Bioprosthetic Heart ValvesJournal of Cardiac Surgery, 1991
- Leaflet geometry and function in porcine bioprosthesesEuropean Journal of Cardio-Thoracic Surgery, 1991
- The versatile homograft and autograft valveThe Annals of Thoracic Surgery, 1989
- Failure and Hydrodynamic Function Testing of Explanted Pericardial and Porcine Bioprosthetic ValvesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1989
- Tissue Buckling as a Mechanism of Bioprosthetic Valve FailureThe Annals of Thoracic Surgery, 1988
- Isolated Mitral Valve Replacement with the Hancock Bioprosthesis: A 13-Year AppraisalThe Annals of Thoracic Surgery, 1984
- Calcific degeneration as the main cause of porcine bioprosthetic valve failureThe American Journal of Cardiology, 1984
- Influence of fixation conditions on the performance of glutaraldehyde-treated porcine aortic valves: towards a more scientific basis.Thorax, 1979
- Stress analysis of the aortic valve during diastole: Important parametersJournal of Biomechanics, 1976
- Dimensions and Geometric Relationships of the Human Aortic Value as a Function of PressureCirculation Research, 1974