Abstract
The measurement of subtle morphologic beat-to-beat variability in the electrocardiogram (ECG)/vectorcardiogram (VCG) is complicated by the presence of noise which is caused by, e.g., respiration and muscular activity. A method was recently presented which reduces the influence of such noise by performing spatial and temporal alignment of VCG loops. The alignment is performed in terms of scaling, rotation and time synchronization of the loops. Using an ECG simulation model based on propagation of action potentials in cardiac tissue, the ability of the method to separate morphologic variability of physiological origin from respiratory activity was studied. Morphologic variability was created by introducing a random variation in action potential propagation between different compartments. The results indicate that the separation of these two activities can be done accurately at low to moderate noise levels (less than 10 microV). At high noise levels, the estimation of the rotation angles was found to break down in an abrupt manner. It was also shown that the breakdown noise level is strongly dependent on loop morphology; a planar loop corresponds to a lower breakdown noise level than does a nonplanar loop.Keywords
This publication has 10 references indexed in Scilit:
- Spatiotemporal QRST cancellation techniques for improved characterization of atrial fibrillation in the surface ECGPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Beat-to-beat QRS variability in the 12-lead ECG and the detection of coronary artery disease.Journal of Electrocardiology, 1998
- Non-invasive assessment of the atrial cycle length during atrial fibrillation in man: introducing, validating and illustrating a new ECG methodCardiovascular Research, 1998
- Vectorcardiographic loop alignment and morphologic beat-to-beat variabilityIEEE Transactions on Biomedical Engineering, 1998
- On the detection of QRS variations in the ECGIEEE Transactions on Biomedical Engineering, 1995
- Simulation of ECG from two pairs of action potentialsClinical Physiology and Functional Imaging, 1993
- Simulation of the electrogram from ion currentsClinical Physiology and Functional Imaging, 1993
- Beat-to-beat electrocardiographic morphology variation in healed myocardial infarctionThe American Journal of Cardiology, 1991
- Vectorcardiogram synthesized from a 12-lead ECG: Superiority of the inverse Dower matrixJournal of Electrocardiology, 1988
- Phase-Invariant Signature AlgorithmAngiology, 1979