A PRESTO‐SENSE sequence with alternating partial‐Fourier encoding for rapid susceptibility‐weighted 3D MRI time series
Open Access
- 26 September 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (4) , 830-838
- https://doi.org/10.1002/mrm.10599
Abstract
A 3D sequence for dynamic susceptibility imaging is proposed which combines echo‐shifting principles (such as PRESTO), sensitivity encoding (SENSE), and partial‐Fourier acquisition. The method uses a moderate SENSE factor of 2 and takes advantage of an alternating partial k‐space acquisition in the “slow” phase encode direction allowing an iterative reconstruction using high‐resolution phase estimates. Offering an isotropic spatial resolution of 4 × 4 × 4 mm3, the novel sequence covers the whole brain including parts of the cerebellum in 0.5 sec. Its temporal signal stability is comparable to that of a full‐Fourier, full‐FOV EPI sequence having the same dynamic scan time but much less brain coverage. Initial functional MRI experiments showed consistent activation in the motor cortex with an average signal change slightly less than that of EPI. Magn Reson Med 50:830–838, 2003.Keywords
Funding Information
- European Union, Marie Curie Fellowship (QLRI-CT-2000-52107)
This publication has 30 references indexed in Scilit:
- fMRI Retinotopic Mapping—Step by StepNeuroImage, 2002
- The relative metabolic demand of inhibition and excitationNature, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- 3D z-shim method for reduction of susceptibility effects in BOLD fMRIMagnetic Resonance in Medicine, 1999
- Composite image formation inz-shimmed functional MR imagingMagnetic Resonance in Medicine, 1999
- Removal of local field gradient artifacts in T2*‐weighted images at high fields by gradient‐echo slice excitation profile imagingMagnetic Resonance in Medicine, 1998
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997
- Multi‐gradient echo with susceptibility inhomogeneity compensation (MGESIC): Demonstration of fMRI in the olfactory cortex at 3.0 TMagnetic Resonance in Medicine, 1997
- Three-dimensional functional magnetic resonance imaging of human brain on a clinical 1.5-T scanner.Proceedings of the National Academy of Sciences, 1995
- A. functional MRI technique combining principles of echo‐shifting with a train of observations (PRESTO)Magnetic Resonance in Medicine, 1993