Linearization Correction of 99mTc-Labeled Hexamethyl-Propylene Amine Oxime (HM-PAO) Image in Terms of Regional CBF Distribution: Comparison to C15O2 Inhalation Steady-State Method Measured by Positron Emission Tomography
- 1 December 1988
- journal article
- research article
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 8 (1_suppl) , S52-S60
- https://doi.org/10.1038/jcbfm.1988.33
Abstract
The radioisotope distribution following intravenous injection of 99mTc-labeled hexamethylpropyleneamine oxime (HM-PAO) in the brain was measured by single photon emission computed tomography (SPECT) and corrected for the nonlinearity caused by differences in net extraction. The “linearization” correction was based on a three compartment model, and it required a region of reference to normalize the SPECT image in terms of regional cerebral blood flow distribution. Two different regions of reference, the cerebellum and the whole brain, were tested. The uncorrected and corrected HM-PAO images were compared with cerebral blood flow (CBF) image measured by the C15O2 inhalation steady state method and positron emission tomography (PET). The relationship between uncorrected HM-PAO and PET–CBF showed a correlation coefficient of 0.85 but tended to saturate at high CBF values, whereas it was improved to 0.93 after the “linearization” correction. The whole-brain normalization worked just as well as normalization using the cerebellum. This study constitutes a validation of the “linearization” correction and it suggests that after linearization the HM-PAO image may be scaled to absolute CBF by employing a global hemispheric CBF value as measured by the nontomographic 133Xe clearance method.Keywords
This publication has 16 references indexed in Scilit:
- A System for Cerebral Blood Flow Measurement Using an H215O Autoradiographic Method and Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1987
- Development of a 99Tcm-labelled radiopharmaceutical for cerebral blood flow imagingNuclear Medicine Communications, 1985
- Design and Evaluation of a Positron Emission TomographJournal of Computer Assisted Tomography, 1985
- Cerebral uptake and retention of 99Tcm-hexamethylpropyleneamine oxime (99Tcm-HM-PAO)Nuclear Medicine Communications, 1985
- Metabolic and Kinetic Considerations in the Use of [125I]HIPDM for Quantitative Measurement of Regional Cerebral Blood FlowJournal of Cerebral Blood Flow & Metabolism, 1985
- Measurement of Cerebral Blood Flow Using Bolus Inhalation of C15O2 and Positron Emission Tomography: Description of the Method and its Comparison with the C15O2 Continuous Inhalation MethodJournal of Cerebral Blood Flow & Metabolism, 1984
- Effect of Tissue Heterogeneity on the Measurement of Cerebral Blood Flow with the Equilibrium C15O2 Inhalation TechniqueJournal of Cerebral Blood Flow & Metabolism, 1983
- Quantitative Image Reconstruction with Weighted Backprojection for Single Photon Emission Computed TomographyJournal of Computer Assisted Tomography, 1983
- HEADTOMEJournal of Computer Assisted Tomography, 1981
- Two Methods for Calculating Regional Cerebral Blood Flow from Emission Computed Tomography of Inert Gas ConcentrationsJournal of Computer Assisted Tomography, 1979