Personnel protection during cardiac catheterization with a comparison of the hazards of undercouch and overcouch X-ray tube mountings
- 1 January 1974
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 47 (553) , 16-23
- https://doi.org/10.1259/0007-1285-47-553-16
Abstract
The doses received by the staff of the cardiac catheterization laboratory of the Brompton Hospital, London, have been measured at various positions upon their bodies. The measurements have been combined with the findings of a radiation survey to compare the hazards associated with the overcouch X-ray tube mounting now employed, with those of the undercouch tube mounting in use for four years previously. It is seen that the advantages of the overcouch X-ray tube are accompanied by increased potential radiation hazards to the staff. In a busy department diligent attention to protection discipline is essential to restrict radiation dosages, to the cardiologist in particular, to the maximum levels given in the Code of Practice (H.M.S.O., 1972).Keywords
This publication has 7 references indexed in Scilit:
- Radiation Exposure to Personnel During Cardiac CatheterizationRadiology, 1973
- Cardiac catheterization.Heart, 1972
- Radiation Exposure to Personnel During Cardiac CatheterizationRadiology, 1971
- Radiation doses delivered to the skin, bone marrow and gonads of patients during cardiac catheterisation and angiocardiographyThe British Journal of Radiology, 1968
- The Distribution of Active Bone Marrow in the AdultPhysics in Medicine & Biology, 1961
- An Improved Method and Filmholder for Personnel MonitoringThe British Journal of Radiology, 1959
- Stray Radiation from Diagnostic X-ray BeamsThe British Journal of Radiology, 1951