Low oxygen extraction fraction in tumours measured with the oxygen-15 steady state technique: effect of tissue heterogeneity
- 1 August 1992
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 65 (776) , 697-700
- https://doi.org/10.1259/0007-1285-65-776-697
Abstract
Several reports have described decreased oxygen extraction fractions in tumours relative to those in normal tissues as measured with the oxygen-15 steady state technique and positron emission tomography. The present simulation study was carried out to assess the influence of tissue heterogeneity on these measured values. It was found that, within the range analyzed, tissue heterogeneity always resulted in underestimations of mean values of oxygen extraction fraction. It must, therefore, be concluded that the oxygen-15 steady state technique is not an accurate method for the assessment of the oxygen status of tumours. This finding should also apply to other pathological conditions, where a significant degree of tissue heterogeneity can not be excluded. More generally, this study demonstrates the need for detailed analyses of sensitivities of tracer kinetic procedures to tissue heterogeneity.Keywords
This publication has 12 references indexed in Scilit:
- Comparative measurement of Regional blood flow, oxygen and glucose utilisation in soft tissue tumour of rabbit with positron imagingThe British Journal of Radiology, 1985
- POSITRON EMISSION TOMOGRAPHY FOR IN-VIVO MEASUREMENT OF REGIONAL BLOOD FLOW, OXYGEN UTILISATION, AND BLOOD VOLUME IN PATIENTS WITH BREAST CARCINOMAThe Lancet, 1984
- Correction for the Presence of Intravascular Oxygen-15 in the Steady-State Technique for Measuring Regional Oxygen Extraction Ratio in the Brain: 1. Description of the MethodJournal of Cerebral Blood Flow & Metabolism, 1983
- Correction for the Presence of Intravascular Oxygen-15 in the Steady-State Technique for Measuring Regional Oxygen Extraction Ratio in the Brain: 2. Results in Normal Subjects and Brain Tumour and Stroke PatientsJournal of Cerebral Blood Flow & Metabolism, 1983
- Effect of Tissue Heterogeneity on the Measurement of Cerebral Blood Flow with the Equilibrium C15O2 Inhalation TechniqueJournal of Cerebral Blood Flow & Metabolism, 1983
- Measurement of regional cerebral blood flow and oxygen utilisation in patients with cerebral tumours using 15O and positron emission tomography: Analytical techniques and preliminary resultsNeuroradiology, 1982
- A Theoretical Study of the Steady-State Model for Measuring Regional Cerebral Blood Flow and Oxygen Utilisation Using Oxygen-15Journal of Computer Assisted Tomography, 1981
- A New Journal and a New Society—Why?Journal of Cerebral Blood Flow & Metabolism, 1981
- Quantitative Measurement of Regional Cerebral Blood Flow and Oxygen Metabolism in Man Using 15O and Positron Emission TomographyJournal of Computer Assisted Tomography, 1980
- The continuous inhalation of Oxygen-15 for assessing regional oxygen extraction in the brain of manThe British Journal of Radiology, 1976