Single radial hemolysis test for rubella immunity and recent infection
- 1 January 1983
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 17 (1) , 28-34
- https://doi.org/10.1128/jcm.17.1.28-34.1983
Abstract
The single radial hemolysis (SRH) test was compared with the hemagglutination inhibition (HI) test for establishing rubella immune status and diagnosing recent infection. Correlation between mean SRH diameters and HI titers greater than or equal to 1:8 was high (R = 0.99). It is suggested that a level of greater than or equal to 5 IU represents low-level antibody and that greater than or equal to 15 IU is a conservative threshold for designation of immunity. Of 343 sera tested, only 1 false-positive was found by SRH with the 5 IU cutoff level. The SRH test could detect serum antibody levels as low as 2.5 IU, whereas 15 IU was generally the limit of resolution of the HI test. Data from sucrose density gradient fractionation of serum demonstrated that neither rubella-specific immunoglobulin M (IgM) nor early postinfection HI-reactive IgG was detected by SRH. However, diagnostic changes in antibody titer measured by SRH were in general greater than those measured by HI. The SRH test showed diagnostic titer changes in some sera containing specific IgM for which no such changes were detected by the HI test. A 2.5-mm difference in hemolytic zone diameters (a fourfold rise in international units) between acute- and convalescent-phase serum pairs was chosen as being of diagnostic significance. This difference was less than the minimum observed difference of 2.9 mm from 59 serum pairs showing diagnostic changes by HI and far exceeded (greater than 3.6 standard deviations) the within-test and individual variability seen for 95 pregnant women from whom samples were obtained during each trimester.This publication has 19 references indexed in Scilit:
- Are many women immunized against rubella unnecessarily?Epidemiology and Infection, 1981
- Evaluation of Commercially Available Diagnostic Test Kits for RubellaThe Journal of Infectious Diseases, 1981
- Description of a technique for the determination of the concentration and quality of rubella virus antibody molecules and experience with testing sera from humans with recent and past rubella infectionArchiv für die gesamte Virusforschung, 1980
- Rubella antibody measured by radial haemolysis. Characteristics and performance of a simple screening method for use in diagnostic laboratoriesEpidemiology and Infection, 1980
- Rubella immunity by four different techniques: results of challenge studiesJournal of Medical Virology, 1980
- Single-Radial-Hemolysis Test for the Assay of Rubella Antibody in Antenatal, Vaccinated, and Rubella Virus-Infected PatientsThe Journal of Infectious Diseases, 1979
- Evaluation of the single radial haemolysis (SRH) technique for rubella antibody measurement.Journal of Clinical Pathology, 1978
- An assessment of radial haemolysis in the detection of rubella antibody.Journal of Clinical Pathology, 1978
- APPLICATION OF THE PASSIVE HAEMOLYSIS TEST FOR THE DETERMINATION OF RUBELLA VIRUS ANTIBODIESActa Pathologica Microbiologica Scandinavica Section B Microbiology, 1975
- DTT Test: A New Method to Differentiate IgM and IgG Erythrocyte Antibodies1Vox Sanguinis, 1974