Frequent ICD Shocks due to Double Sensing in Patients with Bi-Ventricular Implantable Cardioverter Defibrillators
- 1 January 2003
- journal article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 9 (3) , 377-381
- https://doi.org/10.1023/a:1027455713120
Abstract
Biventricular pacing has emerged as a modality for treatment of patients with heart failure. Combined biventricular pacers and implantable cardioverter defibrillators offer treatment of heart failure as well as protection from sudden cardiac death. However, inappropriate ICD shocks as a result of double sensing due to widely spaced ventricular bipoles may pose a significant problem in these patients. We examined the ICD records of twenty-three patients with biventricular ICDs, and evaluated all episodes of double sensing that resulted in aborted or delivered therapy. In follow-up of 3.7 ± 2.6 months, thirty-three shocks in fifteen episodes occurred in five patients (21.7%) due to double sensing. Four patients (17.4%) had aborted shocks due to double sensing. All episodes resulting in shock occurred because of sinus tachycardia or supraventricular tachycardia above the upper programmed pacing rate of the device with resultant AV conduction and double sensing of the nonpaced ventricular depolarization. In conclusion, double sensing of the R-wave is a common and clinically important cause of inappropriate ICD detection and shock in patients with biventricular ICDs. Appropriate programming of the ICD can prevent episodes of inappropriate shocks.Keywords
This publication has 17 references indexed in Scilit:
- Matching approved "nondedicated" hardware to obtain biventricular pacing and defibrillation: feasibility and troubleshooting.Pacing and Clinical Electrophysiology, 2002
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- Effects of Multisite Biventricular Pacing in Patients with Heart Failure and Intraventricular Conduction DelayNew England Journal of Medicine, 2001
- Should stimulation therapy for congestive heart failure be combined with defibrillation backup?The American Journal of Cardiology, 2000
- Reversal of Left Ventricular Remodeling by Synchronous Biventricular Pacing in Heart FailurePacing and Clinical Electrophysiology, 2000
- Efficacy of Biventricular Sensing and Treatment of Ventricular ArrhythmiasPacing and Clinical Electrophysiology, 2000
- The Acute Effects of Transvenous Biventricular Pacing in a Patient With Congestive Heart FailureChest, 2000
- Biventricular Pacing in End-Stage Heart Failure Improves Functional Capacity and Left Ventricular FunctionJournal of Interventional Cardiac Electrophysiology, 2000
- Potential benefit of biventricular pacing in patients with congestive heart failure and ventricular tachyarrhythmiaThe American Journal of Cardiology, 1999
- Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular ArrhythmiaNew England Journal of Medicine, 1996