Cerebral state index during anaesthetic induction: a comparative study with propofol or nitrous oxide
- 29 April 2005
- journal article
- clinical trial
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 49 (6) , 750-753
- https://doi.org/10.1111/j.1399-6576.2005.00737.x
Abstract
Background: Confidently predicting the depth of anaesthesia for the individual patient and independently of drug(s) type using EEG‐based monitors has proven difficult. This open, randomized, explorative study of day surgical patients evaluates the ability of the Cerebral State Monitor™ (Danmeter AB, Odense, Denmark) of anaesthetic depth to identify loss of response (LOR) using either propofol or N20 for induction.Methods: In this open, randomized study, day surgical patients (n=10 in each group) were studied using the Cerebral State Index Monitor™. After baseline measurements, induction to LOR was achieved with either repeated 30‐mg boluses of propofol every second minute or with N20 (after premedication 5 min before with 30 mg propofol) increased every other minute in 15% increments (max. 75%). Sedation level was evaluated every other minute using the Observer's Assessment of Alertness/Sedation scaleResults: Baseline values were 91 (82–98) and 94 (82–100) for N20 and propofol patients, respectively. During induction CSI™ decreased with increasing sedation in patients given propofol (P<0.001) but not in patients given nitrous oxide. Median value at LOR was 56 (40–76) and 95 (87–100) for the propofol and nitrous oxide group of patients, respectively.Conclusion: The Cerebral State Index™ behaves as other depth of anaesthesia monitors with a progressive decrease during propofol induction but loss of consciousness with N20 results in no change in CSI™.Keywords
This publication has 15 references indexed in Scilit:
- Entropy is blind to nitrous oxide. Can we see why?British Journal of Anaesthesia, 2004
- Entropy of EEG during anaesthetic induction: a comparative study with propofol or nitrous oxide as sole agent † †This article is accompanied by Editorial I.British Journal of Anaesthesia, 2004
- Entropy during propofol hypnosis, including an episode of wakefulnessAnaesthesia, 2004
- Correlation of Approximate Entropy, Bispectral Index, and Spectral Edge Frequency 95 (SEF95) with Clinical Signs of “Anesthetic Depth” during Coadministration of Propofol and RemifentanilAnesthesiology, 2003
- Changes in Consciousness, Conceptual Memory, and Quantitative Electroencephalographical Measures During Recovery from Sevoflurane- and Remifentanil-Based AnesthesiaAnesthesia & Analgesia, 2003
- Comparison of Conventional Averaged and Rapid Averaged, Autoregressive-based Extracted Auditory Evoked Potentials for Monitoring the Hypnotic Level during Propofol InductionAnesthesiology, 2002
- Performance of the ARX-derived Auditory Evoked Potential Index as an Indicator of Anesthetic DepthAnesthesiology, 2002
- Effect of nitrous oxide on the bispectral index and the 95% spectral edge frequency of the electroencephalogram during surgeryAnaesthesia, 2001
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997
- Validity and Reliability of the Observer??sJournal of Clinical Psychopharmacology, 1990