PROSTATE CANCER SCREENING WITHIN A PROSTATE SPECIFIC ANTIGEN RANGE OF 3 TO 3.9 NG./ML.: A COMPARISON OF DIGITAL RECTAL EXAMINATION AND FREE PROSTATE SPECIFIC ANTIGEN AS SUPPLEMENTAL SCREENING TESTS
- 1 October 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 166 (4) , 1339-1342
- https://doi.org/10.1016/s0022-5347(05)65764-3
Abstract
Purpose: Performing biopsy in all men with a serum prostate specific antigen (PSA) of 3 to 3.9 ng./ml. increases the sensitivity of prostate cancer screening compared with a PSA cutoff of 4 ng./ml. but decreases specificity and may contribute to over diagnosis. Therefore, we evaluated the detection rate and specificity attributable to digital rectal examination and percent free PSA within the PSA range of 3 to 3.9 ng./ml. Materials and Methods: Serum PSA was determined in 20,716 participants in the Finnish population based screening trial. Supplementary digital rectal examination was offered to men with a PSA of 3 to 3.9 ng./ml. during 1996 to 1998 (protocol 1). Those with a suspicious digital rectal examination finding were referred for biopsy. The screening algorithm was modified by substituting percent free PSA for digital rectal examination with a cutoff of 16% as a biopsy criterion in 1999 (protocol 2). In addition, biopsies were performed in all men with PSA 4 ng./ml. or greater. Results: A total of 23 cancers (2.9%) were detected by digital rectal examination among 801 men, while percent-free PSA resulted in the diagnosis of 13 cases (4.8%) among 270 men with a PSA of 3 to 3.9 ng./ml. The detection rate of tumors with a Gleason score of 5 or greater increased from 1.6% (13 of 801 cases) to 4.4% (12 of 270) in the modified screening program. The PSA cutoff of 3 ng./ml. alone showed 88.6% and 87.5% specificity in protocols 1 and 2 but specificity increased to 93.3% and 91.7% using digital rectal examination and percent free PSA, respectively. Conclusions: Using percent free PSA increased the detection rate of aggressive disease compared with digital rectal examination and provided higher specificity than PSA alone.Keywords
This publication has 19 references indexed in Scilit:
- PROSTATE CANCER DETECTION AT LOW PROSTATE SPECIFIC ANTIGENJournal of Urology, 2000
- Changing role of 3 screening modalities in the European randomized study of screening for prostate cancer (Rotterdam)International Journal of Cancer, 1999
- Use of percentage of free prostate-specific antigen to identify men at high risk of prostate cancer when psa levels are 2.51 to 4 ng/mL and digital rectal examination is not suspicious for prostate cancer: an alternative modelUrology, 1999
- DIGITAL RECTAL EXAMINATION FOR DETECTING PROSTATE CANCER AT PROSTATE SPECIFIC ANTIGEN LEVELS OF 4 NG./ML. OR LESSJournal of Urology, 1999
- European randomized study of prostate cancer screening: first-year results of the Finnish trialBritish Journal of Cancer, 1999
- Evaluation of the Digital Rectal Examination as a Screening Test for Prostate CancerJNCI Journal of the National Cancer Institute, 1998
- CHARACTERISTICS OF SCREENING DETECTED PROSTATE CANCER IN MEN 50 TO 66 YEARS OLD WITH 3 TO 4 NG./ML. PROSTATE SPECIFIC ANTIGENJournal of Urology, 1998
- Prostate cancer detection in men with serum PSA concentrations of 2.6 to 4.0 ng/mL and benign prostate examination. Enhancement of specificity with free PSA measurementsJAMA, 1997
- Serum Prostate Specific Antigen as Pre-Screening Test for Prostate CancerJournal of Urology, 1992
- Histologic grading of prostate cancer: A perspectiveHuman Pathology, 1992