Rapid detection ofShigella dysenteriae andShigella flexneri in faeces by an immunomagnetic assay with monoclonal antibodies
- 1 January 1993
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 12 (1) , 25-32
- https://doi.org/10.1007/bf01997052
Abstract
A rapid and sensitive method for the detection ofShigella dysenteriae type 1 andShigella flexneri serotypes in faeces based on capture of the bacteria with immunomagnetic particles is described. The particles were coated with either of two different monoclonal antibodies specific for the O-antigens ofShigella dysenteriae type 1 andShigella flexneri serotypes. Captured bacteria were detected by an enzyme immunoassay with O-antigen specific rabbit antiserum. The whole assay required 2 to 3 hours to perform and the sensitivity limit was 103 cfu/ml as determined by viable cell counting. One hundred and fifty enterobacteria strains, including 100Shigella strains from a strain collection, and 302 fresh faecal samples were used for the study. AllShigella dysenteriae type 1 andShigella flexneri culture-positive faecal samples were positive in the immunomagnetic assay. In addition 18 of 252 culture-negative faecal samples were positive. The immunomagnetic assay was compared with latex agglutination and indirect immunofluorescence using culture as the reference method. The immunomagnetic assay had a sensitivity of 100%, latex agglutination a sensitivity of 72% with 28% false-negative results, and indirect immunofluorescence a sensitivity of 95%. The immunomagnetic assay was superior in sensitivity since it also detectedShigella in faecal samples up to two days after antibiotic therapy had been started, which both latex agglutination and indirect immunofluorescence failed to do. The high sensitivity in detecting live and dead bacteria, and the ease of performance of the immunomagnetic assay render it an attractive method for detection ofShigella.Keywords
This publication has 13 references indexed in Scilit:
- Efficient production of mouse and rat monoclonal antibodies against the O antigens of Salmonella serogroup C1, using LPS-coated bacteria as immunogenJournal of Immunological Methods, 1990
- Use of a Rapid Latex Agglutination Test to Detect Salmonella and Shigella Antigens from Gram-Negative Enrichment BrothAmerican Journal of Clinical Pathology, 1989
- DIAGNOSIS AND MANAGEMENT OF DYSENTERY BY COMMUNITY HEALTH WORKERSThe Lancet, 1988
- Quantitative differences among various proteins as blocking agents for ELISA microtiter platesJournal of Immunological Methods, 1987
- Biomedical Applications of Monodisperse Magnetic Polymer ParticlesPublished by Springer Nature ,1987
- HLA class I and II typing using cells positively selected from blood by immunomagnetic isolation ‐ a fast and reliable techniqueTissue Antigens, 1986
- [34] The effect of pristane on ascites tumor formation and monoclonal antibody productionPublished by Elsevier ,1986
- Magnetic Monosized Polymer Particles for Fast and Specific Fractionation of Human Mononuclear CellsScandinavian Journal of Immunology, 1985
- Swelling of oligomer-polymer particles. New methods of preparationAdvances in Colloid and Interface Science, 1980
- PEROXIDASE-LABELED ANTIBODY A NEW METHOD OF CONJUGATIONJournal of Histochemistry & Cytochemistry, 1974