Measurement of 60 Hz Voltages Using the Kerr Effect
- 1 December 1972
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 43 (12) , 1839-1841
- https://doi.org/10.1063/1.1685580
Abstract
The Kerr effect has been used to measure 60 Hz alternating voltage up to 30 kV peak. The system behaves much as it does under the influence of a short high‐voltage pulse except that in this case the frequency of the applied voltage is sufficiently low that the space charge effects in the liquid are not negligible.Keywords
This publication has 8 references indexed in Scilit:
- Pulsed Laser Kerr System Polarimeter for Electro-Optical Fringe Pattern Measurement of Transient Electrical ParametersReview of Scientific Instruments, 1972
- Development and Evaluation of Electrooptical High-Voltage Pulse Measurement TechniquesIEEE Transactions on Instrumentation and Measurement, 1970
- A Kerr electro-optical technique for observation and analysis of high-intensity electric fieldsJournal of Research of the National Bureau of Standards, Section C: Engineering and Instrumentation, 1969
- A Transformer-Ratio-Arm Bridge for Measuring Large Capacitors Above 100 VoltsIEEE Transactions on Power Apparatus and Systems, 1968
- Electric conduction in nitrobenzeneChemical Physics Letters, 1968
- Électrodialyse des solvants polairesJournal de Chimie Physique et de Physico-Chimie Biologique, 1968
- Calibration of a Kerr Cell System for High-Voltage Pulse MeasurementsIEEE Transactions on Instrumentation and Measurement, 1968
- Kerr Cell Measuring System for High Voltage PulsesReview of Scientific Instruments, 1964