Pulmonary perfusion measured by means of electrical impedance tomography
- 1 May 1998
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 19 (2) , 263-273
- https://doi.org/10.1088/0967-3334/19/2/013
Abstract
Electrical impedance tomography (EIT) is a recent imaging technique based on electrical impedance, offering the possibility of measuring pulmonary perfusion. In the present study the influence of several pulmonary haemodynamical parameters on the EIT signal were investigated. First, the influence on the systolic wave of the EIT signal (delta Zsys) of stroke volume, large pulmonary artery distensibility (both assessed by means of MRI) and the extent of the pulmonary peripheral vascular bed in 11 emphysematous patients (reduced peripheral vascular bed) and 9 controls (normal peripheral vascular bed) was investigated. Second, the influence of hypoxic pulmonary vasoconstriction on delta Zsys was examined in 14 healthy subjects. Finally, the origin of the diastolic wave was examined in three patients with atrioventricular dissociation. Multiple regression analysis showed that delta Zsys was only dependent on the variable emphysema (p < 0.02), but not dependent on stroke volume (p < 0.3) or pulmonary artery distensibility (p > 0.9). The mean value of delta Zsys for emphysematous patients (131 +/- 32 arbitrary units (AU)) was significantly lower (p < 0.001) than in the control group (200 +/- 39). In the group of healthy subjects delta Zsys decreased significantly (p < 0.001) during hypoxia (193 +/- 38 AU) compared with rest measurements (260 +/- 62 AU). The absence of the diastolic wave in the cardiological patients suggests the influence of reverse venous blood flow on the EIT signal. It is concluded that volume changes in the small pulmonary vessels contribute significantly to the EIT signal. Moreover, the hypoxia induced decrease in delta Zsys indicates the potential of EIT for measuring pulmonary vascular responses to external stimuli.Keywords
This publication has 23 references indexed in Scilit:
- Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configurationPhysiological Measurement, 1996
- The intra- and interobserver variability of impedance cardiography in patients at rest and during exercisePhysiological Measurement, 1996
- Doppler assessment of hypoxic pulmonary vasoconstriction and susceptibility to high altitude pulmonary oedema.Thorax, 1995
- A real-time electrical impedance tomography system for clinical use-design and preliminary resultsIEEE Transactions on Biomedical Engineering, 1995
- The dose-response relationship for hypoxic pulmonary vasoconstrictionRespiration Physiology, 1994
- A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboliPhysiological Measurement, 1994
- Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT imagesClinical Physics and Physiological Measurement, 1992
- Pulmonary artery distensibility and blood flow patterns: A magnetic resonance study of normal subjects and of patients with pulmonary arterial hypertensionAmerican Heart Journal, 1989
- An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusionClinical Physics and Physiological Measurement, 1988
- Localisation of cardiac related impedance changes in the thoraxClinical Physics and Physiological Measurement, 1987