The importance of clinical subsets in interpreting maximal treadmill exercise test results: the role of multiple-lead ECG systems.
- 1 March 1979
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 59 (3) , 560-570
- https://doi.org/10.1161/01.cir.59.3.560
Abstract
Men (200) with normal ECGs at rest had maximum treadmill tests using 14 ECG leads 1 day before their coronary arteriogram. The prevalence of coronary stenoses .gtoreq. 70% was 86% in 87 men with typical angina, 65% in 64 men with probable angina, and 28% in 49 men with nonspecific chest pain (P < 0.001). Among the 117 men who had coronary disease and probable or typical angina, there was more 3-vessel (32% vs 7%; P = 0.06) and proximal left coronary disease (41% vs 14%; P < 0.05) than among the 14 men with coronary lesions and nonspecific chest pain. Prevalence, extent and location of coronary stenoses were different among the clinical subsets. The predictive value of a positive test in any one of 14 leads was 45% (9 of 20) in men with nonspecific chest pain vs 82% (36 of 44) in men with probable angina and 100% (65 of 65) in men with typical angina (P < 0.001). The predictive value of a negative test in 14 leads was 83% (24 of 29) in men with nonspecific chest pain vs 70% (14 of 20) in men with probable angina and 55% (12 of 22) in men with typical angina (NS). In men with probable or typical angina, 92% (33 of 36) of those with a positive test and treadmill work time .ltoreq. 360 s had multivessel disease; only 1 man in 40 with a negative test in 14 leads and treadmill work time > 540 s had 3-vessel disease. The diagnostic impact of maximal treadmill testing using 14 ECG leads is greatest in men with typical and probable angina. In these 2 clinical subsets the presence or absence of horizontal or downsloping ST-segment depression .gtoreq. 1 mm, ST-segment elevation .gtoreq. 1 mm, or a slowly upsloping ST-segment depression .gtoreq. 2 mm at 0.08 s after the J point in any of 14 leads is highly predictive of multivessel disease when used in conjunction with treadmill work time. The predictive value of maximal treadmill testing using 14 ECG leads in men with nonspecific chest pain is less useful. The lower predictive value of a positive test occurs because this clinical subset has less severe coronary disease and a lower prevalence of disease than men with anginal symptoms. Recording a single lead such as CM5 would suffice for the majority of patients in this subset using either horizontal or downsloping ST-segment depression .gtoreq. 1 mm or ST-segment elevation .gtoreq. 1 mm as criteria for positivity.This publication has 28 references indexed in Scilit:
- Bayesian Analysis of Electrocardiographic Exercise Stress TestingNew England Journal of Medicine, 1977
- Real-Time Radionuclide Cineangiography in the Noninvasive Evaluation of Global and Regional Left Ventricular Function at Rest and during Exercise in Patients with Coronary-Artery DiseaseNew England Journal of Medicine, 1977
- False positive diagnostic tests and coronary angiographic findings in 105 presumably healthy males.Circulation, 1976
- Predictive value of laboratory testsThe American Journal of Cardiology, 1975
- Coronary arteriographic findings in 1,000 women under age 50The American Journal of Cardiology, 1975
- Correlation of computer-quantitated treadmill exercise electrocardiogram with arteriographic location of coronary artery diseaseThe American Journal of Cardiology, 1972
- Postexercise electrocardiography: Correlations with coronary arteriography and left ventricular hemodynamicsThe American Journal of Cardiology, 1971
- A comparison of hypoxemia and exercise electrocardiography in coronary artery disease: Diagnostic precision of the methods correlated with coronary angiographyAmerican Heart Journal, 1968
- The use of single plane angiocardiograms for the calculation of left ventricular volume in manAmerican Heart Journal, 1968
- Multiple-Lead Exercise ElectrocardiographyCirculation, 1967