Sampling and storage of blood for determination of ionized calcium
- 1 January 1985
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 45 (2) , 131-138
- https://doi.org/10.3109/00365518509160985
Abstract
We report some new procedures for the determination of ionized calcium using a semi-automatic ICA 1 analyser provided with a new flow-through tonometer unit, TNC 1, in connection with an automatic turntable. Ionized calcium calculated to a standard pH of 7.4 (cCa2+(7.4)) was not significantly different for capillary blood, venous blood and serum in healthy adults; however, a significant difference was found for actual ionized calcium (cCa2+). The effect of erythrocytes on the liquid junction potential was eliminated by use of a new salt bridge solution (sodium formate). Serum samples should be taken as anaerobi-cally as possible to avoid precipitation of calcium complexes when pH increases above 7.9. For measurement of cCa2+ + -pH we developed special capillary tubes. Serum could be stored at 4 d`C for 7 days and at -20 d`C for 45 days without significant change in cCa2+ +(7.4). Capillary blood could be stored at 4 d`C for 4 h without significant change in + and pH or at 4 d`C or 2 0 d`C for 24 h without significant change in cCa2+(7.4). Vein puncture with stasis or muscular exercise caused only a small increase in cCa2+(7.4) (1.5%). The ingestion of food did not affect cCa2+. in healthy adults. 97.5% CO2 equilibrium was obtained in 3 min with the new flow-through tonometer.Keywords
This publication has 29 references indexed in Scilit:
- Elimination of the erythrocyte effect on the liquid junction potential in Potentiometric measurements on whole blood using mixed salt bridge solutionsScandinavian Journal of Clinical and Laboratory Investigation, 1983
- Effects of Sample Freezing on Ion-Selective Electrode Determinations of Serum CalciumClinical Chemistry, 1982
- Evaluation of a new semiautomatic electrode system for simultaneous measurement of ionized calcium and pHScandinavian Journal of Clinical and Laboratory Investigation, 1982
- The effects of stasis with and without exercise on free calcium, various cations, and related parametersClinica Chimica Acta; International Journal of Clinical Chemistry, 1980
- The Effect of the Alkaline Tide on Serum-Ionized Calcium Concentration in ManDigestion, 1977
- Comparative calcium ion determinations in plasma and whole blood with a new calcium ion analyzerClinica Chimica Acta; International Journal of Clinical Chemistry, 1976
- Variation in Plasma Calcium with Induced Changes in Plasma Specific Gravity, Total Protein, and AlbuminBMJ, 1973
- Determination of Ionized Calcium in Serum by Use of an Ion-Selective ElectrodeClinical Chemistry, 1972
- Acid-Base and Blood Gas Parameters — Arterial or Capillary Blood?Scandinavian Journal of Clinical and Laboratory Investigation, 1968
- Sampling and Storing of Blood for Determination of Acid-Rase StatusScandinavian Journal of Clinical and Laboratory Investigation, 1961