A Statistical Aspect of the Coordination of Two Gaps
- 1 March 1965
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. 84 (3) , 232-236
- https://doi.org/10.1109/TPAS.1965.4766183
Abstract
Many problems of insulation coordination are concerned with the protection of an air gap by means of another air gap: protection of the external insulation of a bushing by means of a rod gap, protection of line-to-tower insulation by means of the ground hardware of an insulator string, protection of the open gap of a switch by means of the line-to-ground insulation of the stack, etc. When dealing with stresses caused by switching surges, the inherent dispersion of the dielectric characteristics of the air gaps, i.e., the probability of sparkover and the times-to-sparkover, is such that these problems must be approached with statistical methods. Furthermore, since the designer is interested in the probable number of sparkovers per year and not in the absolute probability of sparkover, the number and the distribution of the stresses which the electric system applies to the insulation considered must be taken into account. This paper intends to provide a tool to the designer and to show how it works by applying the suggested method to the coordination of two rod gaps. In the case examined, the necessary quantitative knowledge will be determined by laboratory tests or taken from previous system studies.Keywords
This publication has 11 references indexed in Scilit:
- Switching-Surge Insulation Level of Porcelain Insulator StringsIEEE Transactions on Power Apparatus and Systems, 1964
- Sparkover Characteristics of Large Gap Spaces and Long Insulation SpringsIEEE Transactions on Power Apparatus and Systems, 1964
- EHV Switch Tests and Switching SurgesIEEE Transactions on Power Apparatus and Systems, 1964
- METIFOR-A Statistical Method for Insulation Design of EHV LinesIEEE Transactions on Power Apparatus and Systems, 1964
- Field Measurement of Surges When Switching in 345-Kv StationsIEEE Transactions on Power Apparatus and Systems, 1964
- Full Scale Surge Testing of VEPCO 500-Kv Line InsulationIEEE Transactions on Power Apparatus and Systems, 1964
- The Determination of Switching Surge Withstand Voltages for EHV Insulation SystemsIEEE Transactions on Power Apparatus and Systems, 1964
- Interim Report-Minimum Electrical Clearances ror Substations Based on Switching Surge RequirementsIEEE Transactions on Power Apparatus and Systems, 1963
- Field Measurement of 345-Kv Lightning Arrester Switching Surge PerrormanceIEEE Transactions on Power Apparatus and Systems, 1963
- Basic Parameters in Determining the Insulation Requirements of Transmission LinesTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1962