Whole Body Composition of Rats Determined by Dual Energy X-Ray Absorptiometry Is Correlated with Chemical Analysis
Open Access
- 1 February 1998
- journal article
- research article
- Published by Elsevier in Journal of Nutrition
- Vol. 128 (2) , 246-250
- https://doi.org/10.1093/jn/128.2.246
Abstract
The use of dual energy X-ray absorptiometry (DXA) is increasing in animal research, but data comparing whole body composition by DXA and chemical analysis (CHEM) in rats are limited. Lean and obese Zucker female rats were used to compare DXA (QDR1000W, Hologic, Waltham, MA) values with CHEM data for percent fat (%FATDXA, %FATCHEM), lean body mass (%PROTDXA, %PROTCHEM) and bone mineral content (%BMCDXA, %ASHCHEM). Four groups of rats (n = 9) were tested for differences in body composition due to consumption of a 100 g guar gum supplement/kg to see if DXA was as sensitive as CHEM in detecting body composition differences induced by diet. The study was analyzed using a split-plot ANOVA where the main plot was a 2 × 2 factorial with phenotype (obese or lean) and treatment (guar gum or control) as the effects, and the subplot was method of detecting body composition (DXA and CHEM), which was treated as a repeated measure. Absolute values for percent fat differed significantly (P < 0.0001) between the two methods as %FATDXA was consistently higher than %FATCHEM. There was not a statistically significant difference due to method for %PROT (P = 0.13). Values for %BMCDXA were significantly (P < 0.0049) lower than %ASHCHEM values. The differences in body composition due to diet treatment were detected similarly by DXA and CHEM. Significant correlations were found between the methods (P < 0.0001) for %FAT (r = 0.99), %PROT (r = 0.96) and %BMC or ASH (r = 0.81). Bland-Altman plots showed good agreement between methods, and regression equations were developed to estimate CHEM values from DXA readings. DXA may provide an alternative method for assessing changes in whole body composition.Keywords
This publication has 13 references indexed in Scilit:
- Improvement in the Accuracy of Dual Energy X-ray Absorptiometry for Whole Body and Regional Analysis of Body Composition: Validation Using Piglets and Methodologic Considerations in InfantsPediatric Research, 1997
- Dual-energy X-ray absorptiometry for the measurement of gross body composition in ratsBritish Journal of Nutrition, 1996
- Dual-energy X-ray absorptiometry for measuring total bone mineral content in the rat: Study of accuracy and precisionBone and Mineral, 1994
- Effects of a Fat Substitute, Sucrose Polyester, on Food Intake, Body Composition, and Serum Factors in Lean and Obese Zucker RatsObesity Research, 1994
- Validation and application of dual-energy x-ray absorptiometry to measure bone mass and body composition in small infantsThe American Journal of Clinical Nutrition, 1993
- Dual energy x-ray absorptiometry: The effects of beam hardening on bone density measurementsMedical Physics, 1992
- Dynamics of Recovery of Body Composition After Overfeeding, Food Restriction or Starvation of Mature Female RatsJournal of Nutrition, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Simple Linear Regression in Medical ResearchNew England Journal of Medicine, 1985
- A Simplified Method for Sampling Small Animal Carcasses for Analyses.Experimental Biology and Medicine, 1963