Phased attenuation correction in respiration correlated computed tomography/positron emitted tomography
- 26 May 2006
- journal article
- Published by Wiley in Medical Physics
- Vol. 33 (6Part1) , 1840-1847
- https://doi.org/10.1118/1.2198170
Abstract
The motion of lungtumors with respiration causes difficulties in the imaging with computed tomography(CT) and positron emitted tomography(PET). Since an accurate knowledge of the position of the tumor and the surrounding tissues is needed for radiation treatment planning, it is important to improve CT/PET image acquisition. The purpose of this study was to evaluate the potential to improve image acquisition using phased attenuation correction in respiration correlated CT/PET, where data of both modalities were binned retrospectively. Respiration correlated scans were made on a Siemens Biograph Sensation 16 CT/PET scanner which was modified to make a low pitch CT scan and list mode PET scan possible. A lollipop phantom was used in the experiments. The sphere with a diameter of 3.1 cm was filled with approximately 20 MBq F - FDG 18 . Three longitudinal movement amplitudes were tested: 2.5, 3.9, and 4.8 cm . After collection of the raw CT data, list mode PET data, and the respiratory signal CT/PET images were binned to ten phases with the help of in-house-built software. Each PET phase was corrected for attenuation with CT data of the corresponding phase. For comparison, the attenuation correction was also performed with nonrespiration correlated (non-RC) CT data. The volume and the amplitude of the movement were calculated for every phase of both the CT and PET data (with phased attenuation correction). Maximum and average activity concentrations were compared between the phased and nonphased attenuation corrected PET. With a standard non-RC CT/PET scan, the volume was underestimated by as much as 46% in CT and the PET volume was overestimated to 370%. The volumes found with RC-CT/PET scanning had average deviations of 1.9% ( ± 4.8 % ) and 1.5% ( ± 3.4 % ) from the actual volume, for the CT and PET volumes, respectively. Evaluation of the maximum activity concentration showed a clear displacement in the images with non-RC attenuation correction, and activity values were on average 14% ( ± 12 % ) lower than with phased attenuation correction. The standard deviation of the maximum activity values found in the different phases was a factor of 10 smaller when phased attenuation correction was applied. In this phantom study, we have shown that a combination of respiration correlated CT/PET scanning with application of phased attenuation correction can improve the imaging of moving objects and can lead to improved volume estimation and a more precise localization and quantification of the activity.Keywords
This publication has 21 references indexed in Scilit:
- Effects of radiotherapy planning with a dedicated combined PET-CT-simulator of patients with non-small cell lung cancer on dose limiting normal tissues and radiation dose-escalation: A planning studyRadiotherapy and Oncology, 2005
- Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scansPhysics in Medicine & Biology, 2005
- Four‐dimensional (4D) PET/CT imaging of the thoraxMedical Physics, 2004
- Positron emission tomography/computed tomography–imaging protocols, artifacts, and pitfallsMolecular Imaging & Biology, 2004
- Literature-based recommendations for treatment planning and execution in high-dose radiotherapy for lung cancerRadiotherapy and Oncology, 2004
- X-ray-based attenuation correction for positron emission tomography/computed tomography scannersSeminars in Nuclear Medicine, 2003
- Respiration-induced Attenuation Artifact at PET/CT: Technical ConsiderationsRadiology, 2003
- Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Respiration‐correlated spiral CT: A method of measuring respiratory‐induced anatomic motion for radiation treatment planningMedical Physics, 2002
- Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancerMedical Physics, 2002