Overall accuracy of the BpTRU??????an automated electronic blood pressure device
- 1 February 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 9 (1) , 47-52
- https://doi.org/10.1097/00126097-200402000-00009
Abstract
The objective of this report is to combine the data from an earlier adult study with the data from a paediatric study in order to determine the overall accuracy of the BpTRU (BPM-100 model) as compared to the recognized standard, auscultatory mercury sphygmomanometer. The individual blood pressure points recorded for both adult and paediatric studies were compared directly to its corresponding observer reference measurements from data collected and stored from the two separate studies. There were 255 sets of readings in the adult study and 162 sets from the paediatric study, which were combined to make 417 pairs of blood pressure readings for this study. The overall observer standard reference mean for the 417 measurements was calculated and the difference between this and the overall mean BPM-100 was calculated with SD and ranges. Measurements within 5, 10 and 15 mmHg agreement were expressed as percentages. A total of 121 subjects were included for this study (85 from the adult study and 36 from the paediatric study). From these, 417 paired measurements were recorded. The mean difference between the BpTRU and the reference standard systolic blood pressure (BP) was 0.47+/-5.40 mmHg with 89.2% measurements within 5 mmHg, 96.4% within 10 mmHg and 99.3% within 15 mmHg. The mean difference between the BpTRU and reference diastolic BP was -2.12+/-5.93 mmHg with 81.1% within 5 mmHg, 92.1% within 10 mmHg and 97.6% within 15 mmHg. The BpTRU has been shown to be an accurate non-invasive blood pressure monitoring device in the general population over a wide range of ages (3-83 years). This combined study meets all requirements of the Association of Advancement of Medical Instrumentation and achieved a grade 'A' in the BHS protocol.Keywords
This publication has 10 references indexed in Scilit:
- Comparison of agreement between different measures of blood pressure in primary care and daytime ambulatory blood pressureBMJ, 2002
- Distribution of blood pressure and hypertension in Canada and the United StatesAmerican Journal of Hypertension, 2001
- How should we measure blood pressure in the doctorʼs office?Blood Pressure Monitoring, 2001
- Comparison of the oscillometric blood pressure monitor (BPM-100 Beta ) with the auscultatory mercury sphygmomanometerBlood Pressure Monitoring, 2001
- Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitorBlood Pressure Monitoring, 2001
- ABC of hypertension: Blood pressure measurementBMJ, 2001
- Evidence based treatment of hypertension: Measurement of blood presssure: an evidence based reviewBMJ, 2001
- The mercury sphygmomanometer should be abandoned before it is proscribedJournal of Human Hypertension, 2000
- Home blood pressure measurement has a stronger predictive power for mortality than does screening blood pressure measurementJournal Of Hypertension, 1998
- How Common Is White Coat Hypertension?JAMA, 1988