Comparison of the oscillometric blood pressure monitor (BPM-100 Beta ) with the auscultatory mercury sphygmomanometer
- 1 June 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 6 (3) , 153-159
- https://doi.org/10.1097/00126097-200106000-00007
Abstract
To compare directly the accuracy of the BPM-100 Beta monitor (an automated oscillometric blood pressure device) with standard auscultatory mercury sphygmomanometry. The BPM-100 Beta was connected in parallel via a T-tube to a mercury sphygmomanometer. The BPM-100 Beta and two trained observers (blinded from each other and from the BPM-100 Beta ) measured the sitting blood pressure simultaneously. Means, standard deviations and ranges were calculated for all the demographic data: age, arm size, heart rate and blood pressure. The agreement between the BPM-100 Beta and the mean of two observers (the reference) was determined and expressed as the mean ± SD, as well as the percentage of differences falling within 5, 10 and 15 mmHg. Of the 92 subjects recruited, 85 (92.4%) met the inclusion criteria, and 391 sets of sitting blood pressure and heart rate measurements were available for analysis. The mean difference between the BPM-100 Beta monitor and the reference was –0.62 ± 6.96 mmHg for systolic blood pressure, –1.48 ± 4.80 mmHg for diastolic blood pressure and 0.14 ± 1.86 beats/min for heart rate. The only limitation of the device was its tendency to underestimate higher systolic blood pressures. This problem has been addressed by a minor change in the algorithm (see the companion publication, Blood Press Monit, 6, 161–165, 2001). The BPM-100 Beta is an accurate blood pressure monitor for the office setting, meeting all requirements of the Association for the Advancement of Medical Instrumentation and achieving an ‘A’ grade according to the British Hypertension Society protocol.Keywords
This publication has 6 references indexed in Scilit:
- Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitorBlood Pressure Monitoring, 2001
- Guidelines for the use of self-blood pressure monitoringJournal Of Hypertension, 2000
- Evaluation of Blood Pressure Measuring DevicesClinical and Experimental Hypertension, 1993
- Prevention of stroke by antihypertensive drug treatment in older persons with isolated systolic hypertension. Final results of the Systolic Hypertension in the Elderly Program (SHEP). SHEP Cooperative Research GroupJAMA, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Blood pressure measurements in obese persons: Comparison of intra-arterial and auscultatory measurements∗The American Journal of Cardiology, 1961