Airway pressure triggered ventilation for preterm neonates
- 1 January 1991
- journal article
- Published by Walter de Gruyter GmbH in jpme
- Vol. 19 (6) , 471-476
- https://doi.org/10.1515/jpme.1991.19.6.471
Abstract
The usefulness of airway pressure triggered ventilation for the preterm newborn has been assessed using a new patient triggered valveless ventilator, the SLE 2000 infant ventilator (SLE 2000). This ventilator performs well at fast rates with no inadvertent positive end expiratory pressure (PEEP) even at rates of 150 breaths per minute (bpm). The ventilator is triggered by a change in airway pressure equal to or exceeding 0.5 cmH2O. If the infant fails to achieve the change in airway pressure which will trigger the ventilator the infant is ventilated at the back-up rate which is predetermined in conventional mode prior to commencing PTV. Infants were ventilated for one hour on a conventional neonatal ventilator, then for one hour on the SLE 2000 in conventional mode without changing the ventilator settings and finally for one hour on the SLE 2000 in patient triggered mode. Arterial blood gases were checked at the end of each hour. During patient triggered ventilation (PTV) the peak pressure, inspiratory time and inspired oxygen concentration were the same as those used during conventional mode. Simultaneous recordings were made of flow, volume, ventilator and oesophageal pressure change, from this recording the trigger delay during PTV was calculated. The trigger delay, being the time lag from the start of spontaneous inspiration, indicated by the negative deflection in the oesophageal pressure trace, and the onset of the ventilator breath. Thirteen infants were included in the study, median gestational age 32 weeks (range 25-35) and birthweight 1640 g (range 838-3038). All were being ventilated for respiratory distress syndrome (RDS) and were 4 days of age.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 8 references indexed in Scilit:
- Comparison of triggering systems for neonatal patient triggered ventilation.Archives of Disease in Childhood, 1991
- Causes of failure of neonatal patient triggered ventilationEarly Human Development, 1990
- The effect of changes in inspiratory time on neonatal triggered ventilationEuropean Journal of Pediatrics, 1990
- Limitations of patient triggered ventilation in neonates.Archives of Disease in Childhood, 1989
- Randomised controlled trial of two methods of weaning from high frequency positive pressure ventilation.Archives of Disease in Childhood, 1989
- Neonatal patient triggered ventilation.Archives of Disease in Childhood, 1988
- Assessment of a new valveless infant ventilator.Archives of Disease in Childhood, 1988
- Patient triggered ventilation in premature neonates.Archives of Disease in Childhood, 1988