In vivo biostability of polyether polyurethanes with polyethylene oxide surface‐modifying end groups; resistance to biologic oxidation and stress cracking
- 22 July 2005
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 75A (1) , 175-184
- https://doi.org/10.1002/jbm.a.30396
Abstract
Polyethylene oxide (PEO) on polymer surfaces has been reported to reduce cellular adhesion, a very desirable property for cardiac pacing leads. A Shore 80A polyether polyurethane with up to 6% PEO surface‐modifying end groups (SME) was evaluated for its chronic in vivo biostability. In a short‐term (12 week) screening test, strained samples appeared to develop the same surface oxidation as unmodified polymer, but did not produce visible cracking ≥500×, prompting a longer‐term study. By the time the longer‐term study was initiated, most of the PEO SME had disappeared from the starting material's surface. After 1 year in vivo, surface oxidation, shallow surface cracking, and environmental stress cracking (ESC) developed on highly strained samples to the point of failure, so that there was no significant difference between the SME polymer and its control (the same polymer without SME). No further change was seen for up to 2 years of implantation. Unstrained PEO SME polymer developed shallow surface cracking, but no ESC up to 2 years of implantation. Thus, PEO SME slightly delayed, but did not stop biodegradation, and under unstrained conditions, has no adverse effect on biostability. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005Keywords
This publication has 11 references indexed in Scilit:
- Shear stress and material surface effects on adherent human monocyte apoptosisJournal of Biomedical Materials Research, 2002
- Physicochemical properties and in vitro biocompatibility of PEO/PTMO multiblock copolymer/segmented polyurethane blendsJournal of Biomaterials Science, Polymer Edition, 2002
- Detection of Hydrophobic End Groups on Polymer Surfaces by Sum-Frequency Generation Vibrational SpectroscopyJournal of the American Chemical Society, 2000
- Effects of surface-coupled polyethylene oxide on human macrophage adhesion and foreign body giant cell formationin vitroJournal of Biomedical Materials Research, 1999
- The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leadsCardiovascular Pathology, 1995
- Chapter 10 BiodegradationCardiovascular Pathology, 1993
- Human plasma α2‐macroglobulin promotes in vitro oxidative stress cracking of pellethane 2363‐80A: In vivo and in vitro correlationsJournal of Biomedical Materials Research, 1993
- An FTIR–ATR investigation of in vivo poly(ether urethane) degradationJournal of Applied Polymer Science, 1992
- Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80AJournal of Biomedical Materials Research, 1990
- Infections Associated with Prosthetic Devices: Magnitude of the ProblemInfectious Disease Clinics of North America, 1989