Unmatched projector/backprojector pairs in an iterative reconstruction algorithm
- 1 May 2000
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 19 (5) , 548-555
- https://doi.org/10.1109/42.870265
Abstract
Computational burden is a major concern when an iterative algorithm is used to reconstruct a three-dimensional (3-D) image with attenuation, detector response, and scatter corrections. Most of the computation time is spent executing the projector and backprojector of an iterative algorithm. Usually, the projector and the backprojector are transposed operators of each other. The projector should model the imaging geometry and physics as accurately as possible. Some researchers have used backprojectors that are computationally less expensive than the projectors to reduce computation time. This paper points out that valid backprojectors should satisfy a condition that the projector/backprojector matrix must not contain negative eigenvalues. This paper also investigates the effects when unmatched projector/backprojector pairs are used.Keywords
This publication has 10 references indexed in Scilit:
- Noise characteristics of SPECT iterative reconstruction with a mis-matched projector-backprojector pairIEEE Transactions on Nuclear Science, 1998
- Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstructionPhysics in Medicine & Biology, 1998
- Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomographyEuropean Journal of Nuclear Medicine and Molecular Imaging, 1997
- Iterative reconstruction with attenuation compensation from cone-beam projections acquired via nonplanar orbitsIEEE Transactions on Nuclear Science, 1997
- Implementation of a model-based nonuniform scatter correction scheme for SPECTIEEE Transactions on Medical Imaging, 1997
- Improving the convergence of iterative filtered backprojection algorithmsMedical Physics, 1994
- Iterative algebraic reconstruction algorithms for emission computed tomography: A unified framework and its application to positron emission tomographyMedical Physics, 1993
- Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correctionIEEE Transactions on Nuclear Science, 1991
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982
- A Method for Attenuation Correction in Radionuclide Computed TomographyIEEE Transactions on Nuclear Science, 1978