In vivo 1H magnetic resonance imaging and spectroscopy of the rat spinal cord using an inductively‐coupled chronically implanted RF coil
Open Access
- 15 November 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (6) , 1216-1222
- https://doi.org/10.1002/mrm.1319
Abstract
An inductively coupled, chronically implanted short-solenoid coil was used to obtain in vivo localized 1H NMR spectra and diffusion-weighted images from a rat spinal cord. A 5 × 8 mm two-turn elliptically shaped solenoid coil was implanted in rats at the site of a T-12 vertebral-level laminectomy. Excitation was achieved solely by a 3 × 3 cm external surface coil, and signal detection was achieved by inductively coupling the external coil to the implanted coil. The image signal-to-noise ratio (SNR) obtained with the inductively-coupled implanted coil was compared with that obtained using a linear or a quadrature external surface coil. The implanted coil provided a gain by over a factor of 3 in SNR. The implanted coil was used to measure localized 1H spectra in vivo at the T13/L1 spinal-cord level within a 1.85 × 1.85 × 4.82 mm (16.5 μL) volume. With 256 averages, a ∼3-s repetition delay and respiratory gating, a high-quality spectrum was acquired in 13 min. In addition, water translational diffusion was measured in three orthogonal directions using a stimulated-echo imaging sequence, with a short echo time (TE), to produce a quantitative map of diffusion in a rat spinal cord in vivo. Magn Reson Med 46:1216–1222, 2001.Keywords
This publication has 32 references indexed in Scilit:
- Visualization of neural tissue water compartments using biexponential diffusion tensor MRIMagnetic Resonance in Medicine, 2001
- Localized 1H NMR spectroscopy of rat spinal cord in VivoMagnetic Resonance in Medicine, 1996
- Dynamic Assessment of Intraspinal Neural Graft Survival Using Magnetic Resonance ImagingExperimental Neurology, 1995
- Long‐term observation of in vivo31P nmr spectra in carbon tetrachloride‐intoxicated rabbit liver using implanted wireless surface coilNMR in Biomedicine, 1995
- Metabolic changes in rabbit spinal cord after trauma: Magnetic resonance spectroscopy studiesAnnals of Neurology, 1989
- Localized proton spectroscopy using stimulated echoesJournal of Magnetic Resonance (1969), 1987
- Wireless implanted magnetic resonance probes for in vivo NMRJournal of Magnetic Resonance (1969), 1986
- Electronic decoupling of surface-coil receivers for NMR imaging and spectroscopyJournal of Magnetic Resonance (1969), 1986
- Self-diffusion NMR imaging using stimulated echoesJournal of Magnetic Resonance (1969), 1985
- An in Vivo NMR probe circuit for improved sensitivityJournal of Magnetic Resonance (1969), 1983