Accessible proteomics space and its implications for peak capacity for zero‐, one‐ and two‐dimensional separations coupled with FT‐ICR and TOF mass spectrometry
- 14 March 2006
- journal article
- review article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 41 (3) , 281-288
- https://doi.org/10.1002/jms.1024
Abstract
The number and wide dynamic range of components found in biological matrixes present several challenges for global proteomics. In this perspective, we will examine the potential of zero‐dimensional (0D), one‐dimensional (1D), and two‐dimensional (2D) separations coupled with Fourier‐transform ion cyclotron resonance (FT‐ICR) and time‐of‐flight (TOF) mass spectrometry (MS) for the analysis of complex mixtures. We describe and further develop previous reports on the space occupied by peptides, to calculate the theoretical peak capacity available to each separations‐mass spectrometry method examined. Briefly, the peak capacity attainable by each of the mass analyzers was determined from the mass resolving power (RP) and the m/z space occupied by peptides considered from the mass distribution of tryptic peptides from National Center for Biotechnology Information's (NCBI's) nonredundant database. Our results indicate that reverse‐phase‐nanoHPLC (RP‐nHPLC) separation coupled with FT‐ICR MS offers an order of magnitude improvement in peak capacity over RP‐nHPLC separation coupled with TOF MS. The addition of an orthogonal separation method, strong cation exchange (SCX), for 2D LC‐MS demonstrates an additional 10‐fold improvement in peak capacity over 1D LC‐MS methods. Peak capacity calculations for 0D LC, two different 1D RP‐HPLC methods, and 2D LC (with various numbers of SCX fractions) for both RP‐HPLC methods coupled to FT‐ICR and TOF MS are examined in detail. Peak capacity production rates, which take into account the total analysis time, are also considered for each of the methods. Furthermore, the significance of the space occupied by peptides is discussed. Copyright © 2006 John Wiley & Sons, Ltd.Keywords
This publication has 39 references indexed in Scilit:
- Continuous pH/Salt Gradient and Peptide Score for Strong Cation Exchange Chromatography in 2D-Nano-LC/MS/MS Peptide Identification for ProteomicsAnalytical Chemistry, 2005
- Statistical Evaluation of Internal and External Mass Calibration Laws Utilized in Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 2005
- Analysis of the Low Molecular Weight Fraction of Serum by LC-Dual ESI-FT-ICR Mass Spectrometry: Precision of Retention Time, Mass, and Ion AbundanceAnalytical Chemistry, 2004
- Dual Electrospray Ionization Source for Confident Generation of Accurate Mass Tags Using Liquid Chromatography Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 2003
- Use of Artificial Neural Networks for the Accurate Prediction of Peptide Liquid Chromatography Elution Times in Proteome AnalysesAnalytical Chemistry, 2003
- Utility of Accurate Mass Tags for Proteome-Wide Protein IdentificationAnalytical Chemistry, 2000
- Role of Accurate Mass Measurement (±10 ppm) in Protein Identification Strategies Employing MS or MS/MS and Database SearchingAnalytical Chemistry, 1999
- Identification of the Components of Simple Protein Mixtures by High-Accuracy Peptide Mass Mapping and Database SearchingAnalytical Chemistry, 1997
- Accuracy Requirements for Peptide Characterization by Monoisotopic Molecular Mass MeasurementsAnalytical Chemistry, 1996
- An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein databaseJournal of the American Society for Mass Spectrometry, 1994