Delayed contact hypersensitivity and surgical glove penetration with acrylic bone cements
- 1 January 1991
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 62 (1) , 24-28
- https://doi.org/10.3109/17453679108993086
Abstract
Skin hypersensitivity was investigated in guinea-pig maximization tests with extracts from pellets of conventional polymethyl-methacrylate (PMMA) bone cements (Palacos R® Simplex RO®) and a new methylmethacrylate/n-decylmethacrylate/isobornylmethacrylate (MMA/DMA/ IBMA) mixture (Boneloc®), but none of the three cements produced evidence of delayed contact hypersensitivity. Testings of the pure monomer compounds showed MMA to be an extreme sensitizer, whereas DMA and IBMA were only mild sensitizers. Fingers from three brands of surgical rubber gloves and a polystyrene-butadiene glove were immersed in water and filled with conventional MMA monomer, MMA/DMA/IBMA monomer or bone cements in the dough state, allowing cure inside the glove. In the surrounding water, no DMA or IBMA could be detected. The MMA concentrations were lower with MMA/DMA/IBMA monomer and curing Boneloc® cement. The most resistant to conventional PMMA cement was one of the rubber gloves, whereas the polystyrene-butadiene glove allowed the highest penetration, and even dissolved in MMA monomer. The potential occupational hazard of skin sensitization is reduced with MMA/ DMA/IBMA bone cement, preferably in combination with rubber gloves; but also polystyrene-butadiene gloves provide adequate protectionKeywords
This publication has 10 references indexed in Scilit:
- Skin protection against methylmethacrylateActa Orthopaedica, 1987
- Contact dermatitis to methyl methacrylateContact Dermatitis, 1984
- Surgical rubber gloves impervious to methylmethacrylate monomerActa Orthopaedica, 1984
- Permeability of Surgeons' Gloves to Methyl MethacrylateActa Orthopaedica, 1983
- Occupational Hazards of Acrylate Bone Cement in Orthopaedic SurgeryActa Orthopaedica, 1983
- Sensitizing potential of 14 mono (meth) acrylates in the guinea pig*Contact Dermatitis, 1982
- Contact Dermatitis in SurgeonsThe Journal of Dermatologic Surgery and Oncology, 1975
- Contact dermatitis in surgeons from methylmethacrylate bone cementJournal of Bone and Joint Surgery, 1975
- Contact Dermatitis from Penetration of Rubber Gloves by Acrylic MonomerBMJ, 1971