Regional pulmonary transit times in humans
- 1 February 1989
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 66 (2) , 844-850
- https://doi.org/10.1152/jappl.1989.66.2.844
Abstract
We measured the frequency distribution of erythrocyte (RBC) transit times in resected lobes of lungs in eight human subjects undergoing thoracotomy for peripheral lung tumors. RBC transit times were measured by the injection of radiolabeled blood flow and volume markers, which were counted in samples from the resected lung. In five of these subjects, the measurements from the resected lung were compared with preoperative measurements of the transit times of radiolabeled RBCs with a gamma camera-computer system. Time-activity curves from the cardiac chambers and the lung or its regions were obtained from which transit times were calculated by the centroid and deconvolution techniques. The reproducibility of transit times measured by this technique was assessed in another eight normal subjects, after sequential bolus injections of radiolabeled cells. The mean transit time of the upper lung region was longer (5.1 +/- 0.5 s) than that of the lower (4.1 +/- 0.6 s, P less than 0.05) in the preoperative study. Similarly, the mean transit time of the upper lung slice was longer (5.5 +/- 0.3 s) than that of the lower slice (3.8 +/- 0.3 s, P less than 0.05) in the resected lung specimens. We conclude that there was good agreement between these techniques and that there are long transit times in the upper regions of human lungs.This publication has 15 references indexed in Scilit:
- Regional differences in erythrocyte transit in normal lungsJournal of Applied Physiology, 1985
- Morphology of Peripheral Airways in Current Smokers and Ex-smokers1–3American Review of Respiratory Disease, 1983
- THE DERIVATION OF THE GAMMA-VARIATE RELATIONSHIP FOR TRACER DILUTION CURVES1983
- Direct Measurement of Pulmonary Capillary Transit TimesScience, 1982
- NON-INVASIVE MEASUREMENT OF CARDIOPULMONARY BLOOD-VOLUME - EVALUATION OF THE CENTROID METHOD1981
- AUTOMATED COMPUTER-PROGRAM FOR RADIONUCLIDE CARDIAC-OUTPUT DETERMINATION1979
- Theory of the Measurement of the Dispersion of an Indicator in Indicator-Dilution StudiesCirculation Research, 1962
- A Mathematical Model of Dilution Curves for Flow StudyCirculation Research, 1961
- A STUDY OF THE TECHNIQUES AND SOURCES OF ERROR IN THE CLINICAL APPLICATION OF THE EXTERNAL COUNTING METHOD OF ESTIMATING CARDIAC OUTPUTThe Lancet Healthy Longevity, 1959
- COMPARISON OF THE FICK AND DYE INJECTION METHODS OF MEASURING THE CARDIAC OUTPUT IN MANAmerican Journal of Physiology-Legacy Content, 1948