Theoretical Design and Analysis of Multivolume Digital Assays with Wide Dynamic Range Validated Experimentally with Microfluidic Digital PCR
- 7 October 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (21) , 8158-8168
- https://doi.org/10.1021/ac201658s
Abstract
This paper presents a protocol using theoretical methods and free software to design and analyze multivolume digital PCR (MV digital PCR) devices; the theory and software are also applicable to design and analysis of dilution series in digital PCR. MV digital PCR minimizes the total number of wells required for “digital” (single molecule) measurements while maintaining high dynamic range and high resolution. In some examples, multivolume designs with fewer than 200 total wells are predicted to provide dynamic range with 5-fold resolution similar to that of single-volume designs requiring 12 000 wells. Mathematical techniques were utilized and expanded to maximize the information obtained from each experiment and to quantify performance of devices and were experimentally validated using the SlipChip platform. MV digital PCR was demonstrated to perform reliably, and results from wells of different volumes agreed with one another. No artifacts due to different surface-to-volume ratios were observed, and single molecule amplification in volumes ranging from 1 to 125 nL was self-consistent. The device presented here was designed to meet the testing requirements for measuring clinically relevant levels of HIV viral load at the point-of-care (in plasma, 1 000 000 molecules/mL), and the predicted resolution and dynamic range was experimentally validated using a control sequence of DNA. This approach simplifies digital PCR experiments, saves space, and thus enables multiplexing using separate areas for each sample on one chip, and facilitates the development of new high-performance diagnostic tools for resource-limited applications. The theory and software presented here are general and are applicable to designing and analyzing other digital analytical platforms including digital immunoassays and digital bacterial analysis. It is not limited to SlipChip and could also be useful for the design of systems on platforms including valve-based and droplet-based platforms. In a separate publication by Shen et al. (J. Am. Chem. Soc., 2011, DOI: 10.1021/ja2060116), this approach is used to design and test digital RT-PCR devices for quantifying RNA.Keywords
This publication has 72 references indexed in Scilit:
- Multiplexed Quantification of Nucleic Acids with Large Dynamic Range Using Multivolume Digital RT-PCR on a Rotational SlipChip Tested with HIV and Hepatitis C Viral LoadJournal of the American Chemical Society, 2011
- Digital Isothermal Quantification of Nucleic Acids via Simultaneous Chemical Initiation of Recombinase Polymerase Amplification Reactions on SlipChipAnalytical Chemistry, 2011
- Advances in developing HIV-1 viral load assays for resource-limited settingsBiotechnology Advances, 2010
- Dead-End Filling of SlipChip Evaluated Theoretically and Experimentally as a Function of the Surface Chemistry and the Gap Size between the Plates for Lubricated and Dry SlipChipsLangmuir, 2010
- Nanoliter Multiplex PCR Arrays on a SlipChipAnalytical Chemistry, 2010
- SlipChip for Immunoassays in Nanoliter VolumesAnalytical Chemistry, 2010
- High-Performance Single Cell Genetic Analysis Using Microfluidic Emulsion Generator ArraysAnalytical Chemistry, 2010
- User-Loaded SlipChip for Equipment-Free Multiplexed Nanoliter-Scale ExperimentsJournal of the American Chemical Society, 2009
- Sensitive digital quantification of DNA methylation in clinical samplesNature Biotechnology, 2009
- Reactions in Droplets in Microfluidic ChannelsAngewandte Chemie International Edition in English, 2006