Instability in human forearm movements studied with feed‐back‐controlled muscle vibration.
- 1 August 1988
- journal article
- research article
- Published by Wiley in The Journal of Physiology
- Vol. 402 (1) , 421-442
- https://doi.org/10.1113/jphysiol.1988.sp017213
Abstract
1. Frequency-modulated vibration was applied to the elbow flexor and extensor tendons to produce reflex movements of the forearm in normal subjects. The modulating (command) signal caused equal and opposite deviations from the 40 Hz carrier frequency so that when flexor vibratory frequency increased, extensor frequency decreased, and vice versa. 2. It is argued that the movements resulted largely from the reflex action of muscle spindle primary afferents whose firing frequency had been ''taken over'' and modulated by the vibration. 3. Bode plots relating forearm movements to command signal (modulating) frequency showed the transfer function of the Ia afferent-CNS-muscle-load system to have a low-pass filter characteristic. The phase lag of movement on command increased progressively with command signal frequency, exceeding 180 deg at 3-4 Hz. 4. The transduced forearm movements were fed back to provide the command signal to the vibrators (and thus indirectly to the spindle afferents) via a filter mimicking the dynamic responsiveness of muscle spindle primary endings. Our aim was to ''break into'' the reflex arc, and re-route it so that we could artificially vary the gain without significantly altering the dynamics of the pathway. 5. Nearly all subjects developed forearm oscillations (tremor) when the gain exceeded a threshold value. Subjects varied widely in their threshold, though for a given subject the threshold remained fairly constant from day to day. The results suggest that reflexly active individuals may not have a large safety margin with respect to forearm instability. 6. The frequency range of the oscillations observed in seven subjects was 3-8 Hz. The frequencies depended upon the level of flexor-extensor co-contraction, and increased from 3 to 5 Hz at 10% co-contraction to 5-8 Hz at 100% co-contraction. An analysis of the mechanical impedance of the arm provided estimates of tremor frequencies consistent with these results. 7. These unexpectedly low tremor frequencies led us to propose that it may be erroneous to expect stretch reflexes to contribute to forearm tremor in the range 8-12 Hz (e.g. physiological and ''enhanced'' physiological tremors). Rather, their contributions should be sought in the range 3-8 Hz (e.g. pathological tremors such as those of Parkinson''s and cerebellar disease).This publication has 19 references indexed in Scilit:
- Rebound excitation as the physiological basis for tremor: a biophysical study of the oscillatory properties of mammalian central neurones in vitroPublished by Springer Nature ,1984
- Action of vibration on the response of cat muscle spindle Ia afferents to low frequency sinusoidal stretching.The Journal of Physiology, 1981
- Comparison of electromyogram spectra with force spectra during human elbow tremor.The Journal of Physiology, 1980
- Enhancement by agonist or antagonist muscle vibration of tremor at the elastically loaded human elbow.The Journal of Physiology, 1980
- Effect of load disturbances during centrally initiated movementsJournal of Neurophysiology, 1978
- Small-signal analysis of response of mammalian muscle spindles with fusimotor stimulation and a comparison with large-signal responsesJournal of Neurophysiology, 1978
- The responses of human muscle spindle endings to vibration during isometric contraction.The Journal of Physiology, 1976
- The relative sensitivity to vibration of muscle receptors of the catThe Journal of Physiology, 1967
- Signal-handling characteristics of load-moving skeletal muscleAmerican Journal of Physiology-Legacy Content, 1966
- THE RESPONSE TO VIBRATION OF THE END ORGANS OF MAMMALIAN MUSCLE SPINDLESJournal of Neurophysiology, 1963