Peripheral nerve stimulation in a whole‐body echo‐planar imaging system
- 1 March 1997
- journal article
- clinical trial
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 7 (2) , 405-409
- https://doi.org/10.1002/jmri.1880070226
Abstract
Echo‐planar techniques in MRI use a rapidly oscillating frequency‐encoding gradient with the potential to produce peripheral nerve stimulation. To evaluate the incidence, type, and location of stimulation in a commercial whole‐body scanner, we studied two groups: (a) 173 consecutive individuals scanned by echo‐planar imaging for other purposes and (b) seven subjects who were scanned with an extensive set of 36 echo‐planar sequences (with prompting after each scan to report any peripheral nerve stimulation) to test the effects of various parameters. Although only 5% of group A reported symptoms of peripheral nerve stimulation, all in group B experienced some type of stimulation, dependent primarily on direction of the oscillating gradient and location of the body within the gradient coil. Maximum stimulation typically occurred 30 to 40 cm from isocenter in the region of maximum dB/dt. Generally, y gradients produced truncal stimulation, and x gradients produced stimulation in the head. When hands were clasped over the abdomen, a tingling in the hands occasionally was felt. Patients should be instructed to keep their hands apart.Keywords
This publication has 10 references indexed in Scilit:
- Magnetostimulation in MRIMagnetic Resonance in Medicine, 1995
- Avoiding peripheral nerve stimulation: Gradient waveform criteria for optimum resolution in echo‐planar imagingMagnetic Resonance in Medicine, 1994
- Limits to neural stimulation in echo‐planar imagingMagnetic Resonance in Medicine, 1993
- Stimulation by Time-varying Magnetic FieldsAnnals of the New York Academy of Sciences, 1992
- Safety Problems of dB/dt Associated with Echo Planar ImagingAnnals of the New York Academy of Sciences, 1992
- Potential Health Risk due to Cardiac Applications of Echo Planar ImagingAnnals of the New York Academy of Sciences, 1992
- Physiological Effects of Fast Oscillating Magnetic Field GradientsJournal of Computer Assisted Tomography, 1991
- Sensory stimulation by time‐varying magnetic fieldsMagnetic Resonance in Medicine, 1990
- Peripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fieldsMedical & Biological Engineering & Computing, 1989
- NON-INVASIVE MAGNETIC STIMULATION OF HUMAN MOTOR CORTEXPublished by Elsevier ,1985