Distortion of Right Superior Pulmonary Vein Anatomy by Balloon Catheters as a Contributor to Phrenic Nerve Injury
- 6 October 2009
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 20 (10) , 1151-1157
- https://doi.org/10.1111/j.1540-8167.2009.01495.x
Abstract
Introduction: Cryothermal, HIFU, and laser catheter‐based balloon technologies have been developed to simplify ablation for AF. Initial enthusiasm for their widespread use has been dampened by phrenic nerve (PN) injury. The interaction between PN and pulmonary vein (PV) geometry contributing to PN injury is unclear. Methods and Results: After right thoracotomy, the PN course along the epicardial right atrial surface was mapped directly in 10 dogs. The location of the PN and its relationship with the right superior (RS) PV, and potential RSPV surface distortions after balloon inflation were established by electroanatomic mapping. In 5 dogs, the PN was captured within the RSPV, but could not be stimulated in the remaining 5 dogs. The distance between the RSPV and the PN was significantly shorter in the captured group than in the noncaptured group (6.3 ± 3.1 mm vs 10.2 ± 3.2 mm, P < 0.001). Importantly, 96% of the captured sites within the RSPV were observed at a distance >5 mm into the PV. The inflated balloon surface anteriorly extended 5.6 ± 3.7 mm outside the PV diameter, with distortion of anatomy narrowing the distance from the balloon surface to the PN to 4.8 ± 2.3 mm. (Distance of the original RSPV‐to‐PN: 9.4 ± 2.7 mm, P < 0.001.) Conclusion: PN injury with balloon technologies may stem from anatomic distortion of the PV orifice/PN relationship, through increasing contact or shortening the relative distance between the ablation site and the PN, even without displacement of the balloon into the PV. These data are important in the refinement of these technologies to improve procedural safety.Keywords
This publication has 21 references indexed in Scilit:
- Safe and Rapid Isolation of Pulmonary Veins Using a Novel Circular Ablation Catheter and Duty‐Cycled RF GeneratorJournal of Cardiovascular Electrophysiology, 2009
- Mechanism of Tissue Heating During High Intensity Focused Ultrasound Pulmonary Vein Isolation: Implications for Atrial Fibrillation Ablation Efficacy and Phrenic Nerve ProtectionJournal of Cardiovascular Electrophysiology, 2008
- One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillationEP Europace, 2008
- Initial Experience Using a Forward Directed, High‐Intensity Focused Ultrasound Balloon Catheter for Pulmonary Vein Antrum Isolation in Patients with Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2007
- Phrenic Nerve Injury After Catheter Ablation: Should We Worry About This Complication?Journal of Cardiovascular Electrophysiology, 2006
- Comparison of Electrode Cooling Between Internal and Open Irrigation in Radiofrequency Ablation Lesion Depth and Incidence of Thrombus and Steam PopCirculation, 2006
- Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial FibrillationCirculation, 2005
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- Gross Structure of the Atriums: More Than an Anatomic Curiosity?Pacing and Clinical Electrophysiology, 2002
- Anatomy of the Left Atrium:Journal of Cardiovascular Electrophysiology, 1999