A Systematical Analysis of In Vivo Contact Forces on Virtual Catheter Tip/Tissue Surface Contact during Cardiac Mapping and Intervention
- 28 June 2008
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (6) , 632-640
- https://doi.org/10.1111/j.1540-8167.2008.01135.x
Abstract
Introduction: While catheter tip/tissue contact has been shown to be an important determinant of ablative lesions in in vitro studies, the impact of contact on the outcomes of mapping and ablation in the intact heart has not been evaluated. Methods and Results: Twelve dogs underwent atrial ablation guided by the Senesi™ robotic catheter remote control system. After intracardiac ultrasound (ICE) validation of contact force measured by an in‐line mechanical sensor, the relationship between contact force and individual lesion formation was established during irrigated‐tipped ablation (flow 17 mL/sec) at 15 watts for 30 seconds. Minimal contact by ICE correlated with force of 4.7 ± 5.8 grams, consistent contact 9.9 ± 8.6 grams and tissue tenting produced 25.0 ± 14.0 grams. Conversely, catheter tip/tissue contact by ICE was predicted by contact force. A contact force of 10–20 and ≥20 grams generated full‐thickness, larger volume ablative lesions than that created with 3 vs 40 ± 42 mm3, P < 0.05). Moderate (10 grams) and marked contact (15–20 grams) application produced 1.5 X greater electroanatomic map volumes that were seen with minimal contact (5 grams) (26 ± 3 cm3 vs 33 ± 6, 39 ± 3 cm3, P < 0.05). The electroanatomic map/CT merge process was also more distorted when mapping was generated at moderate to marked contact force. Conclusion: This study shows that mapping and ablation using a robotic sheath guidance system are critically dependent on generated force. These findings suggest that ablative lesion size is optimized by the application of 10–20 grams of contact force, although mapping requires lower‐force application to avoid image distortions.Keywords
This publication has 27 references indexed in Scilit:
- View-Synchronized Robotic Image-Guided Therapy for Atrial Fibrillation AblationCirculation, 2007
- Regional left atrial voltage in patients with atrial fibrillationHeart Rhythm, 2006
- Novel Robotic Catheter Remote Control System: Feasibility and Safety of Transseptal Puncture and Endocardial Catheter NavigationJournal of Cardiovascular Electrophysiology, 2006
- Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Comparison of Electrode Cooling Between Internal and Open Irrigation in Radiofrequency Ablation Lesion Depth and Incidence of Thrombus and Steam PopCirculation, 2006
- Indication of the radiofrequency induced lesion size by pre-ablation measurementsEP Europace, 2005
- Discrepancies Between Catheter Tip and Tissue Temperature in Cooled-Tip AblationCirculation, 2005
- Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary VeinCirculation, 2004
- Mechanisms for Enlarging Lesion Size During Irrigated Tip Radiofrequency Ablation:. Is There a Virtual Electrode Effect?Journal of Interventional Cardiology, 2004
- Determinants of Lesion Size During Radiofrequency Catheter Ablation: The Role of Electrode‐Tissue Contact Pressure and Duration of Energy DeliveryJournal of Cardiovascular Electrophysiology, 1991