Stent deployment across the aneurysmal neck has been established as one of the endovascular methods to treat intracranial aneurysms with or without coils. The purpose is to study the possible adverse effects of deployment of the new flow-diverter stent-like devices (FD) on the flow characteristics of saccular aneurysm models. Numerical simulations of the blood flow patterns in the artificial models of three aneurysms were studied. One model was designed without an FD stent, the second model with one FD stent, and the third model with two stents. Numerical simulation for incompressible laminar blood flow was conducted in the three artificial cerebral aneurysm models by means of computational fluid dynamics. There was a noticeable increase in the values of the circumferential pressure distributed on the walls of the aneurysm after stent deployment; this led to an increase the tension of the aneurysm surface and was considered to be an adverse effect. This pressure increase was further aggravated by the deployment of another stent. However, there is a beneficial effect of using FD stents, translating into the reduction of the flow velocity inside the aneurysm and wall shear stress at the inflow zone. This reduction decreases further with the deployment of another stent. Aneurysms become tenser after the deployment of one flow-diverter stent and (more tense still) after after the deployment of another stent. This principle should be kept in mind when choosing which group of aneurysms is the best candidate for such a treatment strategy. This study recommends deploying several FD stents during endovascular procedures until complete arrest of the blood flow occurs during the procedure; otherwise, the aneurysm may become tenser and dangerous if a slow blood flow jet still exists inside it at the end of the procedure.Keywords
This publication has 14 references indexed in Scilit:
- Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of TreatmentAmerican Journal of Neuroradiology, 2010
- Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion TreatmentAmerican Journal of Neuroradiology, 2010
- A Mechanism for the Rapid Development of Intracranial Aneurysms: A Case StudyNeurosurgery, 2010
- Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2010
- Coiling of Intracranial AneurysmsStroke, 2009
- CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2009
- CURATIVE RECONSTRUCTION OF A GIANT MIDBASILAR TRUNK ANEURYSM WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2009
- DEFINITIVE RECONSTRUCTION OF CIRCUMFERENTIAL, FUSIFORM INTRACRANIAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2008
- Buenos Aires experience with the Neuroform self-expanding stent for the treatment of intracranial aneurysmsJournal of Neurosurgery, 2005
- Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable CoilsStroke, 2003