Clinical Performance of Automatic Closed‐Loop Stimulation Systems
- 30 June 2003
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 26 (7p1) , 1432-1437
- https://doi.org/10.1046/j.1460-9592.2003.t01-1-00207.x
Abstract
Inos pacemakers use contraction dynamics to regulate the pacing rate according to the Closed‐Loop Stimulation (CLS) principle. The physician can program only the lower and upper rate limits, while the internal rate responsive parameters are continually adjusted to changing patient conditions. Seventy‐two patients with sinus node disease were enrolled in the multicenter Rate Behavior of the Pacing System Inos2 CLS during Daily Life (RAPID) study to evaluate the appropriateness of CLS rates during daily activities and the long‐term stability of the system. The pacemakers clearly differentiated between climbing stairs, descending stairs, and slow walking, with the corresponding peak rates of 104 ± 18, 95 ± 15 , and 88 ± 11 beats/min , respectively ( P < 0.001 for any pair of activities). The peak CLS rate during the color‐word test was significantly higher than that at rest ( 80 ± 8 vs 67 ± 7 beats/min, P = 0.002 ). The 24‐hour heart rate trends retrieved from the pacemaker memory at 3, 6, and 12 months after implantation appeared appropriate in all patients except for two whose pacing rates were occasionally too fast during the night. Mean diurnal and nocturnal rates determined at 3‐month, 6‐month, and 12‐month examinations fluctuated only slightly, from 74.6–75.3 beats/min (diurnal, P = NS ) and from 67.0–68.1 beats/min (nocturnal, P = NS ), indicating a satisfactory long‐term stability of the system. The incidence of atrial pacing events during the entire follow‐up was 82 ± 18% . A 6.5–8.3 beats/min difference, on average, between day and night (P < 0.001) and distinction between different daily activities seem to evidence sensitivity of the automatic CLS‐driven pacemakers to physiological demands despite minimum programming requirements. (PACE 2003; 26[Pt. I]:1432–1437)Keywords
This publication has 13 references indexed in Scilit:
- Closed‐Loop Stimulation Using Intracardiac Impedance as a Sensor Principle: Correlation of Right Ventricular dP/dtmax and Intracardiac Impedance During Dobutamine Stress TestPacing and Clinical Electrophysiology, 2000
- Interindividual comparison of different sensor principles for rate adaptive pacing.Pacing and Clinical Electrophysiology, 1998
- A Comparative Study of Activity and Dual Sensor: Activity and Minute Ventilation Pacing Responses to Ascending and Descending StairsPacing and Clinical Electrophysiology, 1998
- Right ventricular conductance to establish closed-loop pacingEuropean Heart Journal, 1992
- Quality-of-Life in Patients Treated with Atrioventricular Synchronous Pacing Compared to Rate Modulated Ventricular Pacing: A Long-Term, Double-Blind, Crossover StudyPacing and Clinical Electrophysiology, 1992
- The Range of Sensors and Algorithms Used in Rate Adaptive Cardiac PacingPacing and Clinical Electrophysiology, 1992
- Automatic Adjustment of Pacing Parameters Based on Intracardiac Impedance MeasurementsPacing and Clinical Electrophysiology, 1990
- Comparison of the normal sinus node with seven types of rate responsive pacemaker during everyday activity.Heart, 1990
- Comparison of exercise performance of six rate-adaptive right ventricular cardiac pacemakersThe American Journal of Cardiology, 1989
- The effect of age on heart rate in subjects free of heart disease. Studies by ambulatory electrocardiography and maximal exercise stress test.Circulation, 1982