Radiation exposure of multi-row detector spiral computed tomography of the pulmonary arteries: comparison with digital subtraction pulmonary angiography
- 13 November 2002
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 13 (7) , 1496-1500
- https://doi.org/10.1007/s00330-002-1753-z
Abstract
The purpose of this study was to determine and compare the effective dose of multidetector computed tomographic angiography (MDCT) and digital subtraction angiography (DSA) studies for diagnosing a pulmonary embolus (PE). Radiation exposure was measured as computed tomography dose index (MDCT) or as dose-area product (DSA) and was subsequently expressed in the quantity effective dose. Effective doses were obtained in 27 patients who underwent MDCT and in 12 patients who underwent DSA for suspected PE. The MDCT angiography was performed on a Siemens Volume Zoom CT scanner and DSA on a Philips Integris V-3000 system according to standardized protocols. Average effective dose for MDCT angiography of the pulmonary arteries (27 patients) was 4.2 mSv (range 2.2-6.0 mSv). Pulmonary DSA gained an average effective dose (12 patients) of 7.1 mSv (range 3.3-17.3 mSv). Our results show that the effective doses in MDCT angiography studies for PE are moderate and even slightly lower in comparison with pulmonary DSA in a comparable patient group. Variations in patient dose are smaller for MDCT, probably because this procedure can be more strictly protocolized. Patient dose should not be restrictive in the discussion of CTA replacing DSA for diagnosing PE.Keywords
This publication has 13 references indexed in Scilit:
- A rational approach to dose reduction in CT: individualized scan protocolsEuropean Radiology, 2001
- Peripheral Pulmonary Arteries: How Far in the Lung Does Multi-Detector Row Spiral CT Allow Analysis?Radiology, 2001
- Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CTRadiology, 2000
- Clinical Value of Thin Collimation in the Diagnostic Workup of Pulmonary EmbolismAmerican Journal of Roentgenology, 2000
- Spiral Computed Tomography Is Comparable to Angiography for the Diagnosis of Pulmonary EmbolismAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Sensitivity and Specificity of Helical Computed Tomography in the Diagnosis of Pulmonary EmbolismAnnals of Internal Medicine, 2000
- Organ Dose Calculation in Medical X Ray Examinations by the Program PCXMCRadiation Protection Dosimetry, 1998
- Can helical CT replace scintigraphy in the diagnostic process in suspected pulmonary embolism? A retrolective-prolective cohort study focusing on total diagnostic yieldEuropean Radiology, 1998
- An evaluation of the Diamentor transmission ionisation chamber in indicating exposure-area product (R cm2) during diagnostic radiological examinationsPhysics in Medicine & Biology, 1982
- A method for describing the doses delivered by transmission x-ray computed tomographyMedical Physics, 1981