Consequences of leaf calibration errors on IMRT delivery
- 30 January 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (4) , 1147-1156
- https://doi.org/10.1088/0031-9155/52/4/019
Abstract
IMRT treatments using multi-leaf collimators may involve a large number of segments in order to spare the organs at risk. When a large proportion of these segments are small, leaf positioning errors may become relevant and have therapeutic consequences. The performance of four head and neck IMRT treatments under eight different cases of leaf positioning errors has been studied. Systematic leaf pair offset errors in the range of +/-2.0 mm were introduced, thus modifying the segment sizes of the original IMRT plans. Thirty-six films were irradiated with the original and modified segments. The dose difference and the gamma index (with 2%/2 mm criteria) were used for evaluating the discrepancies between the irradiated films. The median dose differences were linearly related to the simulated leaf pair errors. In the worst case, a 2.0 mm error generated a median dose difference of 1.5%. Following the gamma analysis, two out of the 32 modified plans were not acceptable. In conclusion, small systematic leaf bank positioning errors have a measurable impact on the delivered dose and may have consequences for the therapeutic outcome of IMRT.Keywords
This publication has 24 references indexed in Scilit:
- Intensity-modulated radiotherapy significantly reduces xerostomia compared with conventional radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 2006
- An inter-centre quality assurance network for IMRT verification: Results of the ESTRO QUASIMODO projectRadiotherapy and Oncology, 2005
- Adequate margins for random setup uncertainties in head-and-neck IMRTInternational Journal of Radiation Oncology*Biology*Physics, 2005
- The use of film dosimetry of the penumbra region to improve the accuracy of intensity modulated radiotherapyMedical Physics, 2004
- MLC quality assurance techniques for IMRT applicationsMedical Physics, 2003
- Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulationPhysics in Medicine & Biology, 2002
- Requirements for leaf position accuracy for dynamic multileaf collimationPhysics in Medicine & Biology, 2000
- Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancerInternational Journal of Radiation Oncology*Biology*Physics, 1999
- Quality assurance of the dose delivered by small radiation segmentsPhysics in Medicine & Biology, 1998
- Testing of dynamic multileaf collimationMedical Physics, 1996