Increasing information from shotgun proteomic data by accounting for misassigned precursor ion masses
- 23 July 2008
- journal article
- research article
- Published by Wiley in Proteomics
- Vol. 8 (14) , 2791-2797
- https://doi.org/10.1002/pmic.200800045
Abstract
Although mass spectrometers are capable of providing high mass accuracy data, assignment of true monoisotopic precursor ion mass is complicated during data‐dependent ion selection for LC‐MS/MS analysis of complex mixtures. The complication arises when chromatographic peak widths for a given analyte exceed the time required to acquire a precursor ion mass spectrum. The result is that many measured monoisotopic masses are misassigned due to calculation from a single mass spectrum with poor ion statistics based on only a fraction of the total available ions for a given analyte. Such data in turn produces errors in automated database searches, where precursor m/z value is one search parameter. We propose here a postacquisition approach to correct misassigned monoisotopic m/z values that involves peak detection over the entire elution profile and correction of the precursor ion monoisotopic mass. As a result of using this approach to reprocess shotgun proteomic data we increased peptide sequence assignments by 10% while reducing the estimated false positive ratio from 1 to 0.2%. We also show that 4% of the salvaged identifications may be accounted for by correction of mixed tandem mass spectra resulting from fragmentation of multiple peptides simultaneously, a situation which we refer to as accidental CID.Keywords
This publication has 23 references indexed in Scilit:
- On the Proper Use of Mass Accuracy in ProteomicsMolecular & Cellular Proteomics, 2007
- Sub part-per-million mass accuracy by using stepwise-external calibration in fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 2006
- Mass Measurement Accuracy in Analyses of Highly Complex Mixtures Based Upon Multidimensional RecalibrationAnalytical Chemistry, 2006
- Parts per Million Mass Accuracy on an Orbitrap Mass Spectrometer via Lock Mass Injection into a C-trapMolecular & Cellular Proteomics, 2005
- Increased Protein Identification Capabilities through Novel Tandem MS Calibration StrategiesJournal of Proteome Research, 2005
- The Orbitrap: a new mass spectrometerJournal of Mass Spectrometry, 2005
- Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnelJournal of the American Society for Mass Spectrometry, 2005
- De novo sequencing, peptide composition analysis, and composition-based sequencing: A new strategy employing accurate mass determination by fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 2004
- Accurate mass determination of a metabolite of a potential diagnostic imaging drug candidate by high performance liquid chromatography with time-of-flight mass spectrometryRapid Communications in Mass Spectrometry, 1999
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998