Single-Wire Pressure and Flow Velocity Measurement to Quantify Coronary Stenosis Hemodynamics and Effects of Percutaneous Interventions
- 17 February 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 109 (6) , 756-762
- https://doi.org/10.1161/01.cir.0000112571.06979.b2
Abstract
Background— Lack of high-fidelity simultaneous measurements of pressure and flow velocity distal to a coronary artery stenosis has hampered the study of stenosis pressure drop–velocity (ΔP-v) relationships in patients. Methods and Results— A novel 0.014-inch dual-sensor (pressure and Doppler velocity) guidewire was used in 15 coronary lesions to obtain per-beat averages of pressure drop and velocity after an intracoronary bolus of adenosine. ΔP-v relations from resting to maximal hyperemic velocity were constructed before and after stepwise executed percutaneous coronary intervention (PCI). Before PCI, half of the ΔP-v relations revealed the presence of a compliant stenosis, which was stabilized by angioplasty. Fractional flow reserve (FFR), coronary flow reserve (CFVR), and velocity-based indices of stenosis resistance (h-SRv) and microvascular resistance (h-MRv) at maximal hyperemia were compared. Stepwise PCI significantly lowered h-SRv, with an initial marked reduction in hyperemic pressure drop followed by further gains in velocity. A concomitant significant reduction of h-MRv accounted for half of the gain in velocity after PCI. The average magnitude of absolute incremental hemodynamic changes was highest for h-SRv (56.8±39.2%) compared with CFVR (35.3±34.5%, P P Conclusions— ΔP-v relations comprehensively visualize improvements in coronary hemodynamics after PCI. h-SRv is a powerful and sensitive descriptor of the functional gain achieved by PCI, combining information about both pressure gradient and velocity, which are oppositely affected by PCI. Simultaneous assessment of stenosis and microvascular resistance may provide a valuable tool for guidance of PCI.Keywords
This publication has 18 references indexed in Scilit:
- Intracoronary and Intravenous Adenosine 5′-Triphosphate, Adenosine, Papaverine, and Contrast Medium to Assess Fractional Flow Reserve in HumansCirculation, 2003
- Hyperemic Stenosis Resistance Index for Evaluation of Functional Coronary Lesion SeverityCirculation, 2002
- Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-UpCirculation, 2002
- Fluid Dynamics of a Partially Collapsible Stenosis in a Flow Model of the Coronary CirculationJournal of Biomechanical Engineering, 1996
- Flow Rate-Pressure Drop Relation in Coronary Angioplasty: Catheter Obstruction EffectJournal of Biomechanical Engineering, 1996
- Differential characterization of blood flow, velocity, and vascular resistance between proximal and distal normal epicardial human coronary arteries: Analysis by intracoronary Doppler spectral flow velocityAmerican Heart Journal, 1995
- Intracoronary pressure and flow velocity with sensor-tip guidewires: A new methodologic approach for assessment of coronary hemodynamics before and after coronary interventionsThe American Journal of Cardiology, 1993
- Collapse of diseased arteries with eccentric cross sectionJournal of Biomechanics, 1993
- The disease-free wall in coronary atherosclerosis: Its relation to degree of obstructionJournal of the American College of Cardiology, 1985
- Fluid Mechanics of Arterial StenosesJournal of Biomechanical Engineering, 1979